LIEBERT-GP-ENVIRONMENTAL-MIB: Liebert Environmental SNMP OIDs
The MIB module used to register Liebert Environmental SNMP OIDs.
lgpEnvTemperature
This sub-tree is used to register Liebert temperature object identifiers.
lgpEnvHumidity
This sub-tree is used to register Liebert humidity object identifiers.
lgpEnvState
This sub-tree is used to register Liebert environmental state object identifiers.
lgpEnvConfig
This sub-tree is used to register Liebert environmental configuration object identifiers.
lgpEnvControl
This sub-tree is used to register Liebert environmental control object identifiers.
lgpEnvStatistics
This sub-tree is used to register Liebert environmental statistic object identifiers.
lgpEnvTemperatureWellKnown
Liebert well known temperature objects are identified by OIDs that reside in this sub-tree.
lgpEnvTemperatureFahrenheit
This sub-tree contains OIDs that are used to control and monitor temperature using the Fahrenheit temperature scale.
lgpEnvTemperatureCelsius
This sub-tree contains OIDs that are used to control and monitor temperature using the Celsius temperature scale.
lgpEnvTemperatureControlMode
A reference to a temperature description object. The object referenced should not be accessible, but rather be used to provide a unique description of the temperature object that is used for control.
lgpEnvHumidityWellKnown
Liebert well known humidity objects are defined by OIDs that reside in this sub-tree.
lgpEnvHumidityRelative
This sub-tree contains OIDs that are used to control and monitor relative humidity.
lgpEnvStateSystem
The present state of the system.
lgpEnvStateCooling
The present state of the cooling subsystem.
lgpEnvStateHeating
The present state of the heating subsystem.
lgpEnvStateHumidifying
The present state of the humidifier subsystem.
lgpEnvStateDehumidifying
The present state of the dehumidifier subsystem
lgpEnvStateEconoCycle
The present state of the Econ-o-cycle subsystem.
lgpEnvStateFan
The present state of the system fan.
lgpEnvStateGeneralAlarmOutput
The present state of the general alarm output.
lgpEnvStateCoolingCapacity
The percentage of the cooling capacity presently in use.
lgpEnvStateHeatingCapacity
The percentage of the heating capacity presently in use.
lgpEnvStateAudibleAlarm
The present state of the audible alarm output.
lgpEnvStateCoolingUnits
This sub-tree contains OIDs that are used to indicate the status of cooling units.
lgpEnvStateCoolingUnit1
The present state of cooling unit 1.
lgpEnvStateCoolingUnit2
The present state of cooling unit 2.
lgpEnvStateHeatingUnits
This sub-tree contains OIDs that are used to indicate the status of heating units.
lgpEnvStateHeatingUnit1
The present state of heating unit 1.
lgpEnvStateHeatingUnit2
The present state of heating unit 2.
lgpEnvConfigReheatLockout
If locked-out the reheats will not operate even if controller calls for its operation.
lgpEnvConfigHumLockout
If locked-out the humidifier will not operate even if controller calls for its operation.
lgpEnvConfigRestartDelay
When utility power is disrupted, this is the delay interval to wait before restarting the system after the utility power is restored. A Restart Delay of zero denotes a manual restart, the unit will NOT automatically restart.
lgpEnvConfigRemoteShutdown
When in the disabled state, the remote shutdown feature should be locked out. The enabled state is self-describing.
lgpEnvConfigCoolingServiceInterval
The amount of time, in hours, between scheduled maintenance of the cooling system. When the cooling service timer reaches this value an lgpConditionServiceCooling will be activated. Once service has been completed the cooling service timer should be reset to 0.
lgpEnvConfigHumidifierServiceInterval
The amount of time, in hours, between scheduled maintenance of the humidifier. When the humidifier service timer reaches this value an lgpConditionServiceHumidifier will be activated. Once service has been completed humidifier service timer should be reset to 0.
lgpEnvConfigFilterServiceInterval
The amount of time, in hours, between scheduled maintenance of the system filter. When the filter service timer reaches this value an lgpConditionChangeFilter will be activated. Once service has been completed the filter service timer should be reset to 0.
lgpEnvControlShutdownAfterDelay
Setting this object will shutdown (i.e., turn off) the system after the indicated number of seconds. Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will abort the countdown. If the system is already in the desired state at the time the countdown reaches 0, then nothing will happen. When read, lgpEnvControlShutdownAfterDelay will return the number of seconds remaining until shutdown, or -1 if no shutdown countdown is in effect. On some systems, if the agent is restarted while a shutdown countdown is in effect, the countdown may be aborted. Sets to this object override any lgpEnvControlShutdownAfterDelay already in effect.
lgpEnvControlStartupAfterDelay
Setting this object will start the system after the indicated number of seconds. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will abort the countdown. If the system is already on at the time the countdown reaches 0, then nothing will happen. Sets to this object override the effect of any lgpEnvControlStartupAfterDelay countdown in progress. When read, lgpEnvControlStartupAfterDelay will return the number of seconds until startup, or -1 if no startup countdown is in effect. On some systems, if the agent is restarted while a startup countdown is in effect, the countdown is aborted.
lgpEnvStatisticsComp1RunHr
Accumulated run hours of compressor 1.
lgpEnvStatisticsComp2RunHr
Accumulated run hours of compressor 2.
lgpEnvStatisticsFanRunHr
Accumulated run hours of the main fan.
lgpEnvStatisticsHumRunHr
Accumulated run hours of the humidifier.
lgpEnvStatisticsReheat1RunHr
Accumulated run hours of reheat element 1, or hot water reheat.
lgpEnvStatisticsReheat2RunHr
Accumulated run hours of reheat element 2.
lgpEnvStatisticsCoolingModeHrs
Accumulated run hours while lgpEnvStateCooling is on(1).
lgpEnvStatisticsHeatingModeHrs
Accumulated run hours while lgpEnvStateHeating is on(1).
lgpEnvStatisticsHumidifyModeHrs
Accumulated run hours while lgpEnvStateHumidifying is on(1).
lgpEnvStatisticsDehumidifyModeHrs
Accumulated run hours while lgpEnvStateDehumidifying is on(1).
lgpEnvControlTemperature
Temperature measurement used as control feedback.
lgpEnvReturnAirTemperature
Temperature measurement of return air.
lgpEnvSupplyAirTemperature
Temperature measurement of supply air.
lgpAmbientTemperature
Ambient temperature measurement.
lgpInverterTemperature
Temperature measurement of the inverter.
lgpBatteryTempterature
Temperature measurement of the battery.
lgpAcDcConverterTemperature
Temperature measurement of the AC-to-DC Converter.
lgpPfcTemperature
Temperature measurement of the power factor correction circuitry.
lgpLocalTemperature
Temperature measurement of local temperature sensor.
lgpLocal1Temperature
Temperature measurement of local temperature sensor 1.
lgpLocal2Temperature
Temperature measurement of local temperature sensor 2.
lgpEnvTemperatureSettingDegF
The temperature setting used to control the well known temperature object 'lgpEnvControlTemperature'. This setting is cloned in 'lgpEnvTemperatureSettingDegC' with the value converted to Celsius.
lgpEnvTemperatureToleranceDegF
The acceptable variance from 'lgpEnvTemperatureSettingDegF', without initiating a control action. This setting is cloned in 'lgpEnvTemperatureToleranceDegC' with the value converted to Celsius.
lgpEnvTemperatureTableDegF
A list of temperature table entries. The table contains zero, one, or many rows, depending upon the number of temperature objects available. The NMS cannot create or delete rows from the table. The rows are created by the agent based upon the capabilities of the managed device. The entries in this table are cloned in 'lgpEnvTemperatureTableDegC' where Fahrenheit values are converted to Celsius.
lgpEnvTemperatureEntryDegF
This entry defines the contents of the rows for the table 'lgpEnvTemperatureTableDegF'.
lgpEnvTemperatureIdDegF
This OID is used as an index to identify a row in the table 'lgpEnvTemperatureTableDegF'.
lgpEnvTemperatureDescrDegF
A reference to a temperature description object. The object referenced should not be accessible, but rather be used to provide a unique description of the temperature.
lgpEnvTemperatureMeasurementDegF
The measured temperature value.
lgpEnvTemperatureHighThresholdDegF
The high temperature notification threshold. This is the maximum value of 'lgpEnvTemperatureMeasurementDegF' before the agent sends a notification.
lgpEnvTemperatureLowThresholdDegF
The low temperature notification threshold. This is the minimum value of 'lgpEnvTemperatureMeasurementDegF' before the agent sends a notification.
lgpEnvTemperatureSettingDegC
The temperature setting used to control the well known temperature object 'lgpEnvControlTemperature'. This setting is cloned in 'lgpEnvTemperatureSettingDegF' with the value converted to Fahrenheit.
lgpEnvTemperatureToleranceDegC
The acceptable variance from 'lgpEnvTemperatureSettingDegC', without initiating a control action. This setting is cloned in 'lgpEnvTemperatureToleranceDegF' with the value converted to Fahrenheit.
lgpEnvTemperatureTableDegC
A list of temperature table entries. The table contains zero, one, or many rows, depending upon the number of temperature objects available. The NMS cannot create or delete rows from the table. The rows are created by the agent based upon the capabilities of the managed device. The entries in this table are cloned in 'lgpEnvTemperatureTableDegF' where Celsius values are converted to Fahrenheit.
lgpEnvTemperatureEntryDegC
This entry defines the contents of the rows for the table 'lgpEnvTemperatureTableDegC'.
lgpEnvTemperatureIdDegC
This OID is used as an index to identify a row in the table 'lgpEnvTemperatureTableDegC'.
lgpEnvTemperatureDescrDegC
A reference to a temperature description object. The object referenced should not be accessible, but rather be used to provide a unique description of the temperature.
lgpEnvTemperatureMeasurementDegC
The measured temperature value.
lgpEnvTemperatureHighThresholdDegC
The high temperature notification threshold. This is the maximum value of 'lgpEnvTemperatureMeasurementDegC' before the agent sends a notification.
lgpEnvTemperatureLowThresholdDegC
The low temperature notification threshold. This is the minimum value of 'lgpEnvTemperatureMeasurementDegC' before the agent sends a notification.
lgpEnvControlHumidity
Humidity measurement used as control feedback.
lgpEnvReturnAirHumidity
Humidity measurement of return air.
lgpEnvSupplyAirHumidity
Humidity measurement of supply air.
lgpEnvHumiditySettingRel
The humidity setting used to control the well known humidity object 'lgpEnvControlHumidity'. The humidity scale is determined by 'lgpEnvTemperatureControlScale'.
lgpEnvHumidityToleranceRel
Acceptable variance from lgpEnvHumiditySetting, without initiating a control action.
lgpEnvHumidityTableRel
A list of humidity table entries. The table contains zero, one, or many rows, depending upon the number of humidity objects available. The NMS cannot create or delete rows from the table. The rows are created by the agent based upon the capabilities of the managed device.
lgpEnvHumidityEntryRel
This entry defines the contents of the rows for the table 'lgpEnvHumidityTableRel'.
lgpEnvHumidityIdRel
This OID is used as an index to identify a row in the table 'lgpEnvHumidityTableRel'.
lgpEnvHumidityDescrRel
A reference to a humidity description object. The object referenced should not be accessible, but rather be used to provide a unique description of the humidity.
lgpEnvHumidityMeasurementRel
The measured humidity value.
lgpEnvHumidityHighThresholdRel
The high humidity notification threshold. This is the maximum value of 'lgpEnvHumidityMeasurementRel' before the agent sends a notification.
lgpEnvHumidityLowThresholdRel
The low humidity notification threshold. This is the minimum value of 'lgpEnvHumidityMeasurementRel' before the agent sends a notification.