Welcome: Guest
NOTE: This site is no longer maintained. Upgrade to the latest version of ipMonitor ยป

SNMP Center > Mibs > Raw Text View
FOUNDRY-SN-POS-GROUP-MIB: Foundry Packet Over SONET (POS)

This MIB module contains the definitions of Management Objects for Foundry Packet Over SONET (POS).

FOUNDRY-SN-POS-GROUP-MIB DEFINITIONS ::= BEGIN


-- Foundry POS Group MIB Release 1.0.0
-- Revision 0 10/28/99

-- Copyright 1996-1999 Foundry Networks, Inc.
-- All rights reserved.
-- This Foundry Networks SNMP Management Information Base Specification
-- (Specification) embodies Foundry Networks' confidential and
-- proprietary intellectual property. Foundry Networks retains all
-- title and ownership in the Specification, including any
-- revisions.

-- This Specification is supplied "AS IS," and Foundry Networks makes
-- no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.

-- SECTION 1: Top Level Definitions


-- Imports

IMPORTS
Counter, Gauge
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
snPOS
FROM FOUNDRY-SN-ROOT-MIB;

-- textual conventions
-- maximum of ports are 32.

--  Status Values

   POSStatus ::= INTEGER { disabled(0), enabled(1) }

 DisplayString ::=
     OCTET STRING
 -- This data type is used to model textual information taken
 -- from the NVT ASCII character set.  By convention, objects
 -- with this syntax are declared as having
 --
 --      SIZE (0..255)


snPOSInfo OBJECT IDENTIFIER  ::= { snPOS 1  }

-- POS Port table information

snPOSInfoTable OBJECT-TYPE
SYNTAX  SEQUENCE OF SnPOSInfoEntry
ACCESS  not-accessible
STATUS  mandatory
DESCRIPTION
"A specific snPOSInfo group consists of a number of
switch ports.  "
::= { snPOSInfo 1 }

snPOSInfoEntry OBJECT-TYPE
SYNTAX  SnPOSInfoEntry
ACCESS  not-accessible
STATUS  mandatory
DESCRIPTION
"An entry in the snPOSInfo table indicates the
configuration on a specified port. A SNMP SET PDU
for a row of the snPOSInfoTable requires the entired
sequence of the MIB Objects in each
snPOSInfoEntry stored in one PDU.  Otherwise,
GENERR return-value will be returned."
INDEX   {
snPOSInfoPortNum
}
::= { snPOSInfoTable 1 }

SnPOSInfoEntry ::= SEQUENCE {
snPOSInfoPortNum
INTEGER,
snPOSIfIndex
   INTEGER,
snPOSDescr
   DisplayString,
snPOSName
DisplayString,
snPOSInfoSpeed
   INTEGER,
snPOSInfoAdminStatus
INTEGER,
snPOSInfoLinkStatus
INTEGER,
snPOSInfoClock
   INTEGER,
snPOSInfoLoopBack
   INTEGER,
snPOSInfoScrambleATM
   POSStatus,
snPOSInfoFraming
   INTEGER,
snPOSInfoCRC
   INTEGER,
snPOSInfoKeepAlive
   INTEGER,
snPOSInfoFlagC2
   INTEGER,
snPOSInfoFlagJ0
   INTEGER,
snPOSInfoFlagH1
   INTEGER,
   snPOSStatsInFrames
    Counter,
snPOSStatsOutFrames
    Counter,
snPOSStatsAlignErrors
Counter,
   snPOSStatsFCSErrors
Counter,
   snPOSStatsFrameTooLongs
Counter,
snPOSStatsFrameTooShorts
   Counter,
snPOSStatsInDiscard
   Counter,
snPOSStatsOutDiscard
   Counter,
snPOSInOctets
   OCTET STRING,
snPOSOutOctets
   OCTET STRING,
snPOSStatsInBitsPerSec
   Gauge,
snPOSStatsOutBitsPerSec
   Gauge,
snPOSStatsInPktsPerSec
   Gauge,
snPOSStatsOutPktsPerSec
   Gauge,
snPOSStatsInUtilization
   INTEGER (0..10000),
snPOSStatsOutUtilization
   INTEGER (0..10000),
snPOSTagType
   INTEGER
}


snPOSInfoPortNum OBJECT-TYPE
SYNTAX  INTEGER
ACCESS  read-only
STATUS  mandatory
DESCRIPTION
"The port index.
The bit 0 to bit 7: port number.
The bit 8 to bit 11: slot number (slot for chassis only)."
::= { snPOSInfoEntry 1 }


snPOSIfIndex OBJECT-TYPE
   SYNTAX  INTEGER
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
    "In order to identify a particular interface, this
object shall identify the instance of the ifIndex
object, defined in RFC 1213 and RFC 1573."
   ::= { snPOSInfoEntry 2 }


snPOSDescr OBJECT-TYPE
   SYNTAX  DisplayString
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
    "A textual string containing the slot/port information
    about the interface."
   ::= { snPOSInfoEntry 3 }


snPOSName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port Name string."
::= { snPOSInfoEntry 4 }

snPOSInfoSpeed OBJECT-TYPE
SYNTAX  INTEGER {
s155000(1),
s622000(2),
other(3),
s2488000(4)
}
ACCESS  read-write
STATUS  mandatory
DESCRIPTION
"The speed configuration for a port. The values are:
155000
622000
2488000
"
::= { snPOSInfoEntry 5 }


snPOSInfoAdminStatus OBJECT-TYPE
   SYNTAX  INTEGER {
up(1),       -- ready to pass packets
down(2),
testing(3)   -- in some test mode
}
   ACCESS  read-write
   STATUS  mandatory
   DESCRIPTION
"The desired state of all ports.  The
testing(3) state indicates that no operational
packets can be passed.
(same as ifAdminStatus in MIB-II)"
   ::= { snPOSInfoEntry 6 }


snPOSInfoLinkStatus OBJECT-TYPE
   SYNTAX  INTEGER {
    up(1),       -- ready to pass packets
    down(2),
    testing(3)   -- in some test mode
       }
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
       "The current operational state of the interface.
        The testing(3) state indicates that no operational
        packets can be passed.
        (same as ifOperStatus in MIB-II)"
   ::= { snPOSInfoEntry 7 }


snPOSInfoClock  OBJECT-TYPE
   SYNTAX  INTEGER {
    internal(1),
    line(2)
       }
   ACCESS  read-write
   STATUS  mandatory
   DESCRIPTION
"Clock default internal"
   ::= { snPOSInfoEntry 8 }

snPOSInfoLoopBack   OBJECT-TYPE
   SYNTAX  INTEGER {
    line(1),
    internal(2),
    none(3)
       }
   ACCESS  read-write
   STATUS  mandatory
   DESCRIPTION
"Loop back default none"
   ::= { snPOSInfoEntry 9 }

snPOSInfoScrambleATM  OBJECT-TYPE
SYNTAX POSStatus
   ACCESS  read-write
   STATUS  mandatory
   DESCRIPTION
"ATM style scrambling default off"
   ::= { snPOSInfoEntry 10 }

snPOSInfoFraming  OBJECT-TYPE
   SYNTAX  INTEGER {
    sonet(1),
    sdh(2)
       }
   ACCESS  read-write
   STATUS  mandatory
   DESCRIPTION
"Framing default SONET"
   ::= { snPOSInfoEntry 11 }

snPOSInfoCRC  OBJECT-TYPE
   SYNTAX  INTEGER {
    crc32bits(1),
    crc16bits(2)
       }
   ACCESS  read-write
   STATUS  mandatory
   DESCRIPTION
"CRC default 32 bit"
   ::= { snPOSInfoEntry 12 }

snPOSInfoKeepAlive  OBJECT-TYPE
SYNTAX  INTEGER (0..32767)
   ACCESS  read-write
   STATUS  mandatory
   DESCRIPTION
"Keep-alive default 10"
   ::= { snPOSInfoEntry 13 }

snPOSInfoFlagC2  OBJECT-TYPE
SYNTAX  INTEGER (0..255)
   ACCESS  read-write
   STATUS  mandatory
   DESCRIPTION
"C2 flag"
   ::= { snPOSInfoEntry 14 }


snPOSInfoFlagJ0  OBJECT-TYPE
SYNTAX  INTEGER (0..255)
   ACCESS  read-write
   STATUS  mandatory
   DESCRIPTION
"J0 flag"
   ::= { snPOSInfoEntry 15 }

snPOSInfoFlagH1  OBJECT-TYPE
SYNTAX  INTEGER (0..255)
   ACCESS  read-write
   STATUS  mandatory
   DESCRIPTION
"H1 flag"
   ::= { snPOSInfoEntry 16 }

snPOSStatsInFrames OBJECT-TYPE
   SYNTAX  Counter
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
    "The total number of packets received on the interface."
   ::= { snPOSInfoEntry 17 }


snPOSStatsOutFrames OBJECT-TYPE
   SYNTAX  Counter
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
    "The total number of packets transmitted out of the interface."
   ::= { snPOSInfoEntry 18 }


snPOSStatsAlignErrors   OBJECT-TYPE
    SYNTAX     Counter
    ACCESS     read-only
    STATUS     mandatory
    DESCRIPTION
"dot3StatsAlignmentErrors : A count of frames
  received on a particular interface that are
  not an integral number of octets in length
  and do not pass the FCS check.

  The count represented by an instance of this
  object is incremented when the alignmentError
  status is returned by the MAC service to the
  LLC (or other MAC user). Received frames for
  which multiple error conditions obtain are,
  according to the conventions of IEEE 802.3
  Layer Management, counted exclusively according
  to the error status presented to the LLC."
   ::= { snPOSInfoEntry 19 }

snPOSStatsFCSErrors   OBJECT-TYPE
    SYNTAX      Counter
    ACCESS      read-only
    STATUS      mandatory
    DESCRIPTION
"dot3StatsFCSErrors : A count of frames received
  on a particular interface that are an integral
  number of octets in length but do not pass the
  FCS check.

  The count represented by an instance of this
  object is incremented when the frameCheckError
  status is returned by the MAC service to the
  LLC (or other MAC user). Received frames for
  which multiple error conditions obtain are,
  according to the conventions of IEEE 802.3
  Layer Management, counted exclusively according
  to the error status presented to the LLC."
   ::= { snPOSInfoEntry 20 }


snPOSStatsFrameTooLongs   OBJECT-TYPE
    SYNTAX    Counter
    ACCESS    read-only
    STATUS    mandatory
    DESCRIPTION
"dot3StatsFrameTooLongs : A count of frames
  received on a particular interface that
  exceed the maximum permitted frame size.

  The count represented by an instance of this
  object is incremented when the frameTooLong
  status is returned by the MAC service to the
  LLC (or other MAC user). Received frames for
  which multiple error conditions obtain are,
  according to the conventions of IEEE 802.3
  Layer Management, counted exclusively according
  to the error status presented to the LLC."
   ::= { snPOSInfoEntry 21 }


snPOSStatsFrameTooShorts   OBJECT-TYPE
    SYNTAX    Counter
    ACCESS    read-only
    STATUS    mandatory
    DESCRIPTION
" A count of frames received on a particular
interface that below the minimum permitted
frame size."
   ::= { snPOSInfoEntry 22 }

snPOSStatsInDiscard OBJECT-TYPE
   SYNTAX  Counter
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
       "The number of inbound packets which were chosen
        to be discarded even though no errors had been
        detected to prevent their being deliverable to a
        higher-layer protocol.  One possible reason for
        discarding such a packet could be to free up
        buffer space."
   ::= { snPOSInfoEntry 23 }


snPOSStatsOutDiscard OBJECT-TYPE
   SYNTAX  Counter
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
       "The number of outbound packets which were chosen
        to be discarded even though no errors had been
        detected to prevent their being transmitted.  One
        possible reason for discarding such a packet could
        be to free up buffer space."
   ::= { snPOSInfoEntry 24 }

snPOSInOctets OBJECT-TYPE
   SYNTAX  OCTET STRING (SIZE(8))
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
    "The total number of octets received on the interface,
    including framing characters. This object is a 64-bit
counter of the ifInOctets object, defined in RFC 1213.
The octet string is in big-endian byte order."
   ::= { snPOSInfoEntry 25 }


snPOSOutOctets OBJECT-TYPE
   SYNTAX  OCTET STRING (SIZE(8))
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
    "The total number of octets transmitted out of the interface,
    including framing characters. This object is a 64-bit
counter of the ifOutOctets object, defined in RFC 1213.
The octet string is in big-endian byte order."
   ::= { snPOSInfoEntry 26 }


snPOSStatsInBitsPerSec OBJECT-TYPE
   SYNTAX  Gauge
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
    "The number of bits per second received on the interface
    over a 5 minutes interval."
   ::= { snPOSInfoEntry 27 }


snPOSStatsOutBitsPerSec OBJECT-TYPE
   SYNTAX  Gauge
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
    "The number of bits per second transmitted out of the interface
    over a 5 minutes interval."
   ::= { snPOSInfoEntry 28 }


snPOSStatsInPktsPerSec OBJECT-TYPE
   SYNTAX  Gauge
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
    "The number of packets per second received on the interface
    over a 5 minutes interval."
   ::= { snPOSInfoEntry 29 }


snPOSStatsOutPktsPerSec OBJECT-TYPE
   SYNTAX  Gauge
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
    "The number of packets per second transmitted out of the interface
    over a 5 minutes interval."
   ::= { snPOSInfoEntry 30 }


snPOSStatsInUtilization OBJECT-TYPE
   SYNTAX  INTEGER (0..10000)
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
    "The input network utilization in hundredths of a percent
    over a 5 minutes interval."
   ::= { snPOSInfoEntry 31 }


snPOSStatsOutUtilization OBJECT-TYPE
   SYNTAX  INTEGER (0..10000)
   ACCESS  read-only
   STATUS  mandatory
   DESCRIPTION
    "The output network utilization in hundredths of a percent
    over a 5 minutes interval."
   ::= { snPOSInfoEntry 32 }

snPOSTagType OBJECT-TYPE
SYNTAX  INTEGER {
tagged(1),
untagged(2)
}
ACCESS  read-only
STATUS  mandatory
DESCRIPTION
"For tagged port, we could have multiple VLANs
per port."
::= {snPOSInfoEntry  33}

END