-- ciscoMgx82xxDs1MIB
--   The MIB for DS1/E1 interface configuration and
--   Alarm Configuration for Line Cards/Service Modules
--   in MGX products.
--
-- March 2003, Subra Hegde
--
-- Copyright (c) 2003 by cisco Systems, Inc.
-- All rights reserved.
-- ****************************************************************

CISCO-MGX82XX-DSX1-MIB DEFINITIONS ::= BEGIN
IMPORTS
   MODULE-IDENTITY,
   OBJECT-TYPE,
   Integer32,
   Counter32
                              FROM SNMPv2-SMI
   MODULE-COMPLIANCE,
   OBJECT-GROUP               FROM SNMPv2-CONF
   dsx1Line                   FROM BASIS-MIB
   ciscoWan                   FROM CISCOWAN-SMI;

ciscoMgx82xxDsx1MIB MODULE-IDENTITY
   LAST-UPDATED    "200303310000Z"
   ORGANIZATION    "Cisco Systems, Inc."
   CONTACT-INFO
           "       Cisco Systems
                       Customer Service

               Postal: 170 W Tasman Drive
                       San Jose, CA  95134
                       USA

                       Tel: +1 800 553-NETS

               E-mail: cs-wanatm@cisco.com"
   DESCRIPTION
       "The MIB module to configure DS1/E1 interface
       objects. This mib also contains the alarm
       configuration of DS1/E1 interfaces. This mib
       is supported in T1/E1 service modules."

   REVISION    "200303310000Z"
   DESCRIPTION
       "Initial version of the MIB.

       The content of this MIB was originally available
       in SMIv1 version. The MIB has been converted to
       SMIv2 version and descriptions of some of the objects
       have been modified."
   ::= { ciscoWan 58 }


dsx1CnfGrp OBJECT IDENTIFIER ::= { dsx1Line 1 }
dsx1AlmCnfGrp OBJECT IDENTIFIER ::= { dsx1Line 2 }
dsx1AlmGrp OBJECT IDENTIFIER ::= { dsx1Line 3 }
dsx1CntGrp OBJECT IDENTIFIER ::= { dsx1Line 4 }

--
-- ds1 interface configuration table
--

dsx1CnfGrpTable OBJECT-TYPE
SYNTAX   SEQUENCE OF Dsx1CnfGrpEntry
MAX-ACCESS not-accessible
STATUS   current
DESCRIPTION
"The DS1/E1 Configuration table. The table size is
given by the value of lineNumofValidEntries
"
::= { dsx1CnfGrp 1 }

dsx1CnfGrpEntry OBJECT-TYPE
SYNTAX   Dsx1CnfGrpEntry
MAX-ACCESS not-accessible
STATUS   current
DESCRIPTION
   "An entry in the DS1 Configuration table."
       INDEX { lineNum }
::= { dsx1CnfGrpTable 1 }

Dsx1CnfGrpEntry ::=
SEQUENCE {
   lineNum                    Integer32,
           lineConnectorType          INTEGER,
   lineEnable                 INTEGER,
   lineType                   INTEGER,
   lineCoding                 INTEGER,
         lineLength                 INTEGER,
   lineXmtClockSource         INTEGER,
   lineLoopbackCommand        INTEGER,
   lineSendCode               INTEGER,
   lineLoopbackCodeDetection  INTEGER,
   lineUsedTimeslotsBitMap    Integer32,
   lineBERTEnable             INTEGER,
   lineBERTPattern            INTEGER,
   lineBERTResult             INTEGER,
   bERTResultClrButton        INTEGER
    }

lineNum OBJECT-TYPE
SYNTAX   Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS     current
DESCRIPTION
   "This object is the identifier of a DS1/E1
   Interface on a managed device. If there is an
   ifEntry that is directly associated with this
   and only this DS1/E1 interface, it should have
   the same value as ifIndex.  Otherwise, number
   the ds1LineIndices with an unique identifier
   following the rules of choosing a number that
   is greater than ifNumber and numbering the
   inside interfaces (e.g., equipment side) with
   even numbers and outside interfaces (e.g,
   network side) with odd numbers.

           The supported ranges depend upon the type of
           the card(4 port/8 port etc):

             For 4 port card             : 1 - 4
             For 8 port card             : 1 - 8
             For 2 Port Channelized card : 56 (28*2)."
::= { dsx1CnfGrpEntry 1 }

lineConnectorType OBJECT-TYPE
SYNTAX  INTEGER {
   db15(1),
   bnc(2),
                   rj48(3),
   unused(4),
   smb(5)
  }
MAX-ACCESS read-write
STATUS     current
DESCRIPTION
           "This variable indicates  the  connector as well
   as the backcard type. 1 = T1; 2 = E1.
   This field is set to unused(4) for FRSM-VHS cards."
::= { dsx1CnfGrpEntry 2 }

lineEnable  OBJECT-TYPE
SYNTAX INTEGER {
   disable(1),
         enable(2),
           modify(3)
}
MAX-ACCESS read-write
  STATUS     current
  DESCRIPTION
         "This variable disables, enables or modifies a line
            1 - disable
      2 - enable
      3 - modify
    In FRSM-2CT3, if the DS3 line is enabled, then the DS1
    channels for that line will all be automatically enabled.
    No independent enable/disable is allowed for each of the
    28 DS1 lines in FRSM-2CT3."
DEFVAL {disable}
::= { dsx1CnfGrpEntry 3 }

lineType OBJECT-TYPE
SYNTAX  INTEGER {
   dsx1ESF            (1),
   dsx1D4             (2),
   dsx1E1             (3),
   dsx1E1CRC          (4),
   dsx1E1MF           (5),
   dsx1E1CRC-MF       (6),
   dsx1E1clearchannel (7),
                   dsx1E1Q50          (8),
                   dsx1E1Q50CRC       (9)
  }
MAX-ACCESS read-write
STATUS     current
DESCRIPTION
"This variable indicates  the  variety  of  DS1
Line  implementing  this  circuit.  The type of
circuit affects the number of bits  per  second
      that  the circuit can reasonably carry, as well
as the interpretation of the  usage  and  error statistics.
The values, in sequence, describe:
TITLE:        SPECIFICATION:
dsx1ESF       Extended SuperFrame DS1
dsx1D4        AT&T D4 format DS1
dsx1E1        CCITT Recommendation G.704
      (Table 4a)
dsx1E1-CRC    CCITT Recommendation G.704
                      (Table 4b)
dsxE1-MF      G.704 (Table 4a) with TS16
                      multiframing enabled
dsx1E1-CRC-MF G.704 (Table 4b) with TS16
                      multiframing enabled
dsx1E1clearchannel E1 clear channel, all DS0s can be used
                dsx1E1Q50     G.704 (table 14) In TS16 bits 5,7,8 will be
                              set to 100 for all other cases bits 5,7,8 will
                              have a value of 111.
                dsx1E1Q50CRC  same as dsx1E1Q50 but with CRC.

NOTE: All E1, E1-CRC, E1-MF or E1-CRC-MF are using DS0
               on slot 1 for signaling and E1-MF or E1-CRC-MF use DS0
               on slot 17 for synchronization.
(Slot 1 and 16 is based on index 1 to 32 DS0)
All DS0s can be used for any port when lineType is
dsx1E1clearchannel.
On a CESM card, only 'dsx1E1clearchannel' option is supported.

               When the lineType is dsx1E1Q50 the bits 5,7,8 of TS16
               of frame zero will be forced to 100 else it will be 111.

      The default value for T1 is 'dsx1ESF' and for E1
               is 'dsx1E1CCS'."
::= { dsx1CnfGrpEntry 4 }

lineCoding OBJECT-TYPE
SYNTAX  INTEGER {
                    dsx1JBZS (1),
                    dsx1B8ZS (2),
                    dsx1HDB3 (3),
                    dsx1AMI  (4),
    unused   (5)
  }
MAX-ACCESS read-write
STATUS     current
DESCRIPTION
"This variable describes the  variety  of  Zero
Code  Suppression  used  on  the link, which in
turn affects a number of its characteristics.

dsx1JBZS(1): refers the Jammed  Bit  Zero suppression
            in  which  the  AT&T specification of at
                            least one pulse every 8 bit periods is
                            literally  implemented  by forcing a pulse
                            in bit 8 of each channel.  Thus, only seven
                            bits per  chan- nel, or 1.344 Mbps, is available
                            for data.

dsx1B8ZS(2): refers to the use of a specified  pattern
            of  normal  bits  and  bipolar violations
            which are used to replace a sequence  of  eight
                            zero bits.

E1 links, with or without CRC, use dsx1HDB3  or
        dsx1AMI.

        dsx1AMI(4): refers to a mode wherein no  zero  code
                           suppression  is  present  and the line encoding
                           does not solve the problem directly. In this
                   application, the higher layer must provide data
                   which meets or exceeds the  pulse  density
                   requirements, such as inverting HDLC data.

The default value for T1 is 'dsx1JBZS' and for E1
is 'dsx1HDB3'.
               This field is not applicable for FRSM-VHS cards
               and is set to notUsed(5)."
::= { dsx1CnfGrpEntry 5 }

lineLength OBJECT-TYPE
SYNTAX  INTEGER {
lineLength0To110Feet   (1),
lineLength110To220Feet (2),
lineLength220To330Feet (3),
lineLength330To440Feet (4),
lineLength440To550Feet (5),
lineLength550To660Feet (6),
lineLength660FeetPlus  (7),
lineLength-75-Ohm      (8),
lineLength-120-Ohm     (9),
lineLength0To131Feet   (10),
lineLength131To262Feet (11),
lineLength262To393Feet (12),
lineLength393To524Feet (13),
lineLength524To655Feet (14),
lineLength655FeetPlus  (15),
notRequired            (16)
}
  MAX-ACCESS read-write
STATUS     current
DESCRIPTION
"This is not a standard RFC 1407 DS1 variable, it is
specific to BASIS implementation. It specifies the line length:
1 - 0 to 110 ft (T1 line only)
2 - 110 to 220 ft (T1 line only)
3 - 220 to 330 ft (T1 line only)
4 - 330 to 440 ft (T1 line only)
5 - 440 to 550 ft (T1 line only)
6 - 550 to 660 ft (T1 line only)
7 - greater than 660 ft (T1 line only)
8 - 75 ohms (E1 line only (BNC))
9 - 120 ohms (E1 line only (DB-15))

The default value for T1 is 1, for E1, if the connector
type is DB15 then the default is 9, if BNC, it's 8.
For FRSM-2CT3, the line length of DS1 has no meaning
as there are no physical DS1 lines. So, for this
card, the value is set to notRequired (16).
"
::= { dsx1CnfGrpEntry 6 }

lineXmtClockSource OBJECT-TYPE
   SYNTAX  INTEGER {
               loopTiming  (1),
               localTiming (2)
              }
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "The source of Transmit Clock.

              loopTiming(1): indicates that the recovered
                       receive clock is used as the
                             transmit clock.
              localTiming(2): indicates  that  a  local  clock
                        source is used."
   DEFVAL {loopTiming}
   ::= { dsx1CnfGrpEntry 7 }

lineLoopbackCommand OBJECT-TYPE
SYNTAX  INTEGER {
                   dsx1NoLoop      (1),
                   dsx1RemoteLoop  (2),
                   dsx1LocalLoop   (3),
                   dsx1PayloadLoop (4)
  }
        MAX-ACCESS read-write
        STATUS     current
        DESCRIPTION
"This variable represents the  loopback  confi-
        guration of the DS1 interface.  Agents support-
        ing read/write access should return badValue in
        response to a requested loopback state that the
        interface does not support.  The values mean:

        dsx1NoLoop
            Not in the loopback state.  A device  that
            is not capable of performing a loopback on
            the interface shall always return this  as
            it's value.

        dsx1RemoteLoop
            The received signal at this  interface  is
            looped  through  the device. Typically the
            received signal is  looped  back  for
            retransmission  after  it has passed through
            the device's framing function.

        dsx1LocalLoop
            The local data is looped back
                dsx1PayloadLoop
                        This will loop only the payload and not
                        framing/sync bit.
"
DEFVAL {dsx1NoLoop}
::= { dsx1CnfGrpEntry 8 }

lineSendCode OBJECT-TYPE
SYNTAX  INTEGER {
                   dsx1SendNoCode      (1),
                   dsx1SendLineCode    (2),
                   dsx1SendPayloadCode (3),
                   dsx1SendResetCode   (4)
  }
MAX-ACCESS read-write
STATUS     current
DESCRIPTION
        "This variable indicates what type of  code  is
        being sent across the DS1 interface by the dev-
        ice.  The values mean:

        dsx1SendNoCode
            sending looped or normal data

        dsx1SendLineCode
            sending a request for a line loopback

        dsx1SendPayloadCode
            sending a request for a payload loopback

        dsx1SendResetCode
            sending a loopback termination request

"
DEFVAL {dsx1SendNoCode}
::= { dsx1CnfGrpEntry 9 }

lineUsedTimeslotsBitMap OBJECT-TYPE
SYNTAX     Integer32(0..2147483647)
  MAX-ACCESS read-only
STATUS     current
DESCRIPTION
   "Bit map of used DS0 for this line."
::= { dsx1CnfGrpEntry 10 }

lineLoopbackCodeDetection OBJECT-TYPE
       SYNTAX  INTEGER {
                   codeDetectDisabled(1),
                   codeDetectEnabled(2)
                }
       MAX-ACCESS read-write
       STATUS     current
       DESCRIPTION
               "Enable detection of line Loopback Codes
               "
DEFVAL {codeDetectDisabled}
       ::= { dsx1CnfGrpEntry 11 }

lineBERTEnable OBJECT-TYPE
SYNTAX INTEGER {
   disable (1),
   enable  (2)
}
MAX-ACCESS read-write
       STATUS  current
       DESCRIPTION
"This variable enables Bit Error Rate Testing(BERT)."
DEFVAL { disable }
::= { dsx1CnfGrpEntry 12 }

lineBERTPattern OBJECT-TYPE
SYNTAX  INTEGER {
             allZeros         (1),
                   allOnes          (2),
                   alternateONeZero (3),
                   doubleOneZero    (4),
                   userOneWords     (5),
                   userTwoWords     (6),
                   userThreeWords   (7),
                   userFourWords    (8),
                   fifteenBit       (9),
                   twentyBit        (10),
                   twentyBitQRSS    (11),
                   twentythreeBit   (12)
               }
        MAX-ACCESS read-write
        STATUS     current
        DESCRIPTION
          "This variable determines BERT pattern to transmit
"
DEFVAL { allZeros }
::= { dsx1CnfGrpEntry 13 }

lineBERTResult OBJECT-TYPE
   SYNTAX INTEGER {
   failed(1),
   passed(2)
}
   MAX-ACCESS read-write
   STATUS  current
   DESCRIPTION
       "This shows the result of the BERT."
   DEFVAL { failed }
   ::= { dsx1CnfGrpEntry 14 }

bERTResultClrButton OBJECT-TYPE
   SYNTAX     INTEGER {
                  noaction (1),
  clear    (2)
}
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "This clears the result of the BERT."
   DEFVAL { noaction }
   ::= { dsx1CnfGrpEntry 15 }

lineNumofValidEntries OBJECT-TYPE
SYNTAX   Integer32 (0..128)
MAX-ACCESS read-only
STATUS   current
DESCRIPTION
   "The number of DS1 configuration entries (regardless
   of their current configuration) in the dsx1CnfGrpTable."
::= { dsx1CnfGrp 2 }

dsx1CntGrpTable OBJECT-TYPE
   SYNTAX SEQUENCE OF Dsx1CntGrpEntry
   MAX-ACCESS not-accessible
   STATUS current
   DESCRIPTION
       "The DS1 Counter table. This table contains
       statistics since the system was up or last
       re-initialization."
  ::= { dsx1CntGrp 1 }

dsx1CntGrpEntry OBJECT-TYPE
   SYNTAX Dsx1CntGrpEntry
   MAX-ACCESS  not-accessible
   STATUS  current
   DESCRIPTION
       "An entry in the DS1 counter table."
   INDEX { cntLineNum }
   ::= { dsx1CntGrpTable 1 }

Dsx1CntGrpEntry ::=
   SEQUENCE {
       cntLineNum           Integer32,
rcvLOSCount          Counter32,
rcvOOFCount          Counter32,
rcvRAICount          Counter32,
rcvFECount           Counter32,
counterClearButton   INTEGER
   }

cntLineNum OBJECT-TYPE
   SYNTAX     Integer32 (1..2147483647)
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This object identifies the DS1/E1 interface.
       The value for this object must be same as the
       value of lineNum from dsx1CnfGrpTable."
::= { dsx1CntGrpEntry 1 }

rcvLOSCount OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "The number of times the Loss of Signal was detected
       with or without integrating to LOS alarm."
   ::= { dsx1CntGrpEntry 2 }

rcvOOFCount OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
   "The number of times the Out of Frame was detected
   with or without integrating to OOF alarm."
   ::= { dsx1CntGrpEntry 3 }

rcvRAICount OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "The number of times Yellow Alarms was detected with
       or without integrating to RAI alarm."
   ::= { dsx1CntGrpEntry 4 }

rcvFECount OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "The number of Framing Pattern Errors encountered by
       a DS1 interface."
   ::= { dsx1CntGrpEntry 5 }

counterClearButton OBJECT-TYPE
   SYNTAX  INTEGER {
                   noaction(1),
                   clear (2)
           }
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "This variable is used to clear all the counters."
   ::= { dsx1CntGrpEntry 6 }


-- ------------------------------------------------------------------------
-- ds1AlmConfig group
--
-- This group contains ds1 line alarm configuration table
-- ------------------------------------------------------------------------

dsx1AlmCnfGrpTable OBJECT-TYPE
   SYNTAX SEQUENCE OF Dsx1AlmCnfGrpEntry
   MAX-ACCESS not-accessible
   STATUS current
   DESCRIPTION
       "The DS1 interface alarm configuration table.
       "
   ::= { dsx1AlmCnfGrp 1 }
dsx1AlmCnfGrpEntry OBJECT-TYPE
   SYNTAX Dsx1AlmCnfGrpEntry
   MAX-ACCESS  not-accessible
   STATUS  current
   DESCRIPTION
       "An entry in the DS1 Alarm Configuration table."
   INDEX { almCnfLineNum }
   ::= { dsx1AlmCnfGrpTable 1 }

Dsx1AlmCnfGrpEntry ::=
   SEQUENCE {
almCnfLineNum           Integer32,
redSeverity            INTEGER,
rAISeverity                INTEGER,
      nEAlarmUpCount             Integer32,
nEAlarmDownCount                Integer32,
nEAlarmThreshold                Integer32,
fEAlarmUpCount                  Integer32,
fEAlarmDownCount                Integer32,
fEAlarmThreshold                Integer32,
       statisticalAlarmSeverity        INTEGER,
lCV15MinThreshold               Integer32,
       lCV24HrThreshold                Integer32,
lES15MinThreshold               Integer32,
       lES24HrThreshold                Integer32,
lSES15MinThreshold              Integer32,
       lSES24HrThreshold               Integer32,
cRC15MinThreshold               Integer32,
       cRC24HrThreshold                Integer32,
cRCES15MinThreshold             Integer32,
       cRCES24HrThreshold              Integer32,
cRCSES15MinThreshold            Integer32,
       cRCSES24HrThreshold             Integer32,
sEFS15MinThreshold              Integer32,
       sEFS24HrThreshold               Integer32,
aISS15MinThreshold              Integer32,
       aISS24HrThreshold               Integer32,
uAS15MinThreshold               Integer32,
       uAS24HrThreshold                Integer32
                }

almCnfLineNum OBJECT-TYPE
   SYNTAX     Integer32 (1..2147483647)
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This object identifies the DS1/E1 interface.
       The value for this object must be same as the
       value of lineNum from dsx1CnfGrpTable."
   ::= { dsx1AlmCnfGrpEntry 1 }

redSeverity OBJECT-TYPE
   SYNTAX INTEGER {
   minor(1),
           major(2)
               }
   MAX-ACCESS read-write
   STATUS  current
   DESCRIPTION
       "This variable is used to setup the severity of RED
       alarm. So when RED alarm is detected by the card, an
       alarm with appropriate severity status will be sent."
   DEFVAL { major }
   ::= { dsx1AlmCnfGrpEntry 2 }

rAISeverity OBJECT-TYPE
   SYNTAX INTEGER {
                   minor(1),
                   major(2)
           }
   MAX-ACCESS read-write
   STATUS  current
   DESCRIPTION
       "This variable is used to setup the severity of RAI
       alarm. So when LOS alarm is detected the card, an
       alarm with appropriate severity status will be sent."
   DEFVAL { minor }
   ::= { dsx1AlmCnfGrpEntry 3 }

nEAlarmUpCount OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "This parameter specifies the integration counter,
       the local alarms are LOS and LOF. Default value
       is 6 and update counter every 10 ms to reach the
       threshold set in threshold object.
       This is the up counter."
   DEFVAL { 6 }
   ::= { dsx1AlmCnfGrpEntry 4 }

nEAlarmDownCount OBJECT-TYPE
   SYNTAX  Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS current
   DESCRIPTION
       "This parameter specifies the integration counter,
       the Near-End alarms are LOS and LOF. Default value
       is 1 and update counter every 10 ms to reach 0.
       This is the down counter."
   DEFVAL { 1 }
   ::= { dsx1AlmCnfGrpEntry 5 }

nEAlarmThreshold OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "The value set in this object determines the value
       to declare Near-End alarm. A count of 1500 gives
       2.5 sec to declare LOS with an up count value of
       6."
   DEFVAL { 1500 }
   ::= { dsx1AlmCnfGrpEntry 6 }

fEAlarmUpCount OBJECT-TYPE
   SYNTAX  Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS current
   DESCRIPTION
       "This parameter specifies the integration counter,
       the Far-End alarms are AIS and YEL. Default value
       is 6 and update counter 10 ms to reach the
       threshold set in threshold object.
       This is the up counter."
   DEFVAL { 6 }
   ::= { dsx1AlmCnfGrpEntry 7 }

fEAlarmDownCount OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "This parameter specifies the integration counter,
       the Far-End alarms are AIS and YEL. Default value
       is 1 and update counter every 10 ms to reach 0.
       This is the down counter."
   DEFVAL { 1 }
   ::= { dsx1AlmCnfGrpEntry 8 }

fEAlarmThreshold OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "The value set in this object determines the value
       to declare Far-End alarm. A count of 1500 gives 2.5
       secs to declare LOS with an up count value of 6."
   DEFVAL { 1500 }
   ::= { dsx1AlmCnfGrpEntry 9 }

statisticalAlarmSeverity OBJECT-TYPE
   SYNTAX INTEGER {
                   minor(1),
                   major(2),
                   inhibit(3)
               }
   MAX-ACCESS read-write
   STATUS  current
   DESCRIPTION
       "This variable is used to setup the severity of Statistical
       alarm. So when any statistical alarm is detected by the card,
       an alarm with appropriate severity status will be sent."
   ::= { dsx1AlmCnfGrpEntry 10 }

lCV15MinThreshold OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "Code Violation - is the occurrence of a received CRC-6
       code that is not identical to the corresponding locally.
       calculated code. The value set in this object determines
       the value which when exceeded in a 15 minute window causes
       a statistical alarm to be declared."
   DEFVAL { 14 }
   ::= { dsx1AlmCnfGrpEntry 11 }

lCV24HrThreshold OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "Code Violation - is the occurence of a received CRC-6
       code that is not identical to the corresponding locally.
       The value set in this object determines the value
       which when exceeded in a sliding 24 hour window causes
       a statistical alarm to be declared. The threshold is
       checked every 15 minutes for the preceding 24 hour interval"
       DEFVAL { 134 }
   ::= { dsx1AlmCnfGrpEntry 12 }

lES15MinThreshold OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "Errored Second - is any second with at least one
       code violation. The value set in this object determines
       the value which when exceeded in a 15 minute window causes
       a statistical alarm to be declared."
   DEFVAL { 12 }
   ::= { dsx1AlmCnfGrpEntry 13 }

lES24HrThreshold OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "Errored Second - is any second with at least one
       code violation. The value set in this object determines
       the value which when exceeded in a sliding 24 hour window
       causes a statistical alarm to be declared. The threshold is
       checked every 15 minutes for the preceding 24 hour interval"
   DEFVAL { 121 }
   ::= { dsx1AlmCnfGrpEntry 14 }

lSES15MinThreshold OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "Severely Errored Second - is any second with 15 or more
       code violations. The value set in this object determines
       the value which when exceeded in a 15 minute window causes
       a statistical alarm to be declared."
   DEFVAL { 10 }
   ::= { dsx1AlmCnfGrpEntry 15 }

lSES24HrThreshold OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "Severely Errored Second - is any second with 15 or more
       code violations. The value set in this object determines
       the value which when exceeded in a sliding 24 hour window causes
       a statistical alarm to be declared. The threshold is
       checked every 15 minutes for the preceding 24 hour interval"
   DEFVAL { 100 }
   ::= { dsx1AlmCnfGrpEntry 16 }

cRC15MinThreshold OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "The value set in this object determines the value
       which when exceeded in a 15 minute window causes
       a statistical alarm to be declared."
   DEFVAL { 14 }
   ::= { dsx1AlmCnfGrpEntry 17 }

cRC24HrThreshold OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "The value set in this object determines the value
       which when exceeded in a sliding 24 hour window causes
       a statistical alarm to be declared. The threshold is
       checked every 15 minutes for the preceding 24 hour interval"
   DEFVAL { 134 }
   ::= { dsx1AlmCnfGrpEntry 18 }

cRCES15MinThreshold OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "The value set in this object determines the value
       which when exceeded in a 15 minute window causes
       a statistical alarm to be declared."
   DEFVAL { 12 }
::= { dsx1AlmCnfGrpEntry 19 }

cRCES24HrThreshold OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "The value set in this object determines the value
       which when exceeded in a sliding 24 hour window causes
       a statistical alarm to be declared. The threshold is
       checked every 15 minutes for the preceding 24 hour interval"
   DEFVAL { 121 }
   ::= { dsx1AlmCnfGrpEntry 20 }

cRCSES15MinThreshold OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "The value set in this object determines the value
       which when exceeded in a 15 minute window causes
       a statistical alarm to be declared."
   DEFVAL { 10 }
   ::= { dsx1AlmCnfGrpEntry 21 }

cRCSES24HrThreshold OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "The value set in this object determines the value
       when exceeded in a sliding 24 hour window causes
       a statistical alarm to be declared. The threshold is
       checked every 15 minutes for the preceding 24 hour interval"
   DEFVAL { 100 }
   ::= { dsx1AlmCnfGrpEntry 22 }

sEFS15MinThreshold OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "Severely Errored Framing Second - is a count of one-second
       intervals containing one or more SEF events.
       The value set in this object determines the value
       which when exceeded in a 15 minute window causes
       a statistical alarm to be declared."
   DEFVAL { 2 }
   ::= { dsx1AlmCnfGrpEntry 23 }

sEFS24HrThreshold OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "Severely Errored Framing Second - is a count of one-second
       intervals containing one or more SEF events.
       The value set in this object determines the value
       which when exceeded in a sliding 24 hour window causes
       a statistical alarm to be declared. The threshold is
       checked every 15 minutes for the preceding 24 hour interval"
   DEFVAL { 17 }
::= { dsx1AlmCnfGrpEntry 24 }

aISS15MinThreshold OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "Alarm Indication Signal Second - is a count of one-second
       intervals containing one or more incoming AIS.
       The value set in this object determines the value
       which when exceeded in a 15 minute window causes
       a statistical alarm to be declared."
   DEFVAL { 2 }
   ::= { dsx1AlmCnfGrpEntry 25 }

aISS24HrThreshold OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "Alarm Indication Signal Second - is a count of one-second
       intervals containing one or more incoming AIS.
       The value set in this object determines the value
       which when exceeded in a sliding 24 hour window causes
       a statistical alarm to be declared. The threshold is
       checked every 15 minutes for the preceding 24 hour interval"
   DEFVAL { 17 }
   ::= { dsx1AlmCnfGrpEntry 26 }

uAS15MinThreshold OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "Unavailable Second - is a count of seconds during
       which the DS1 Layer service is unavailable.
       The value set in this object determines the value
       which when exceeded in a 15 minute window causes
       a statistical alarm to be declared."
   DEFVAL { 10 }
::= { dsx1AlmCnfGrpEntry 27 }

uAS24HrThreshold OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "Unavailable Second - is a count of seconds during
       which the DS1 Layer service is unavailable.
       The value set in this object determines the value
       which when exceeded in a sliding 24 hour window causes
       a statistical alarm to be declared. The threshold is
       checked every 15 minutes for the preceding 24 hour interval"
   DEFVAL { 10 }
   ::= { dsx1AlmCnfGrpEntry 28 }


-- ------------------------------------------------------------------------
-- ds1Alm group
--
-- This group contains ds1 line alarm table
-- ------------------------------------------------------------------------

dsx1AlmGrpTable OBJECT-TYPE
   SYNTAX SEQUENCE OF Dsx1AlmGrpEntry
   MAX-ACCESS not-accessible
   STATUS current
   DESCRIPTION
       "The DS1 interface alarm configuration table."
   ::= { dsx1AlmGrp 1 }

dsx1AlmGrpEntry OBJECT-TYPE
   SYNTAX Dsx1AlmGrpEntry
   MAX-ACCESS  not-accessible
   STATUS  current
   DESCRIPTION
       "An entry in the DS1 Alarm table. Each entry
       represents the current, 15 minute and 24 Hour bucket
       intervals for different performance parameters."
   INDEX { almLineNum }
   ::= { dsx1AlmGrpTable 1 }

Dsx1AlmGrpEntry ::=
   SEQUENCE {
       almLineNum                Integer32,
       lineAlarmState        Integer32,
       lineStatisticalAlarmState   Integer32,
       lCVCurrent                  Counter32,
       lCV15MinBucket              Counter32,
       lCV24HrBucket               Counter32,
       lESCurrent                  Counter32,
       lES15MinBucket              Counter32,
       lES24HrBucket               Counter32,
       lSESCurrent                 Counter32,
       lSES15MinBucket             Counter32,
       lSES24HrBucket              Counter32,
       cRCCurrent                  Counter32,
       cRC15MinBucket              Counter32,
       cRC24HrBucket               Counter32,
       cRCESCurrent                Counter32,
       cRCES15MinBucket            Counter32,
       cRCES24HrBucket             Counter32,
       cRCSESCurrent               Counter32,
       cRCSES15MinBucket           Counter32,
       cRCSES24HrBucket            Counter32,
       sEFSCurrent                 Counter32,
       sEFS15MinBucket             Counter32,
       sEFS24HrBucket              Counter32,
       aISSCurrent                 Counter32,
       aISS15MinBucket             Counter32,
       aISS24HrBucket              Counter32,
       uASCurrent                  Counter32,
       uAS15MinBucket              Counter32,
       uAS24HrBucket               Counter32,
       percentEFS                  Integer32,
       alarmClrButton    INTEGER
   }

almLineNum OBJECT-TYPE
   SYNTAX     Integer32 (1..2147483647)
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This object identifies the DS1/E1 interface.
       The value for this object must be same as the
       value of lineNum from dsx1CnfGrpTable."
   ::= { dsx1AlmGrpEntry 1 }

lineAlarmState OBJECT-TYPE
   SYNTAX Integer32 (0..65535)
   MAX-ACCESS read-only
   STATUS  current
   DESCRIPTION
       "This variable is a bitmap of the DSX1 Line Alarms.
       A value of zero indicates no alarms.
       Itemized below are the individual bits:
       BitPosition    Alarm
       -----------    -----
       0              Receiving RAI
       1              Transmitting RAI
       2              Receiving AIS
       3              Transmitting AIS
       4              Receiving OOF
       5              Receiving LOS
       6              Near End Local Loopback in effect
       7              Near End Remote Loopback in effect
       8              Near End Remote Payload Loopback
       9              Receiving CRC MF OOF (E1)
       10             Receiving Sig MF OOF (E1)
       11             Receiving MF RAI (E1)
       12             Receiving MF AIS (E1)
       13             BERT in effect
       14             Far End Remote Loopback in effect
       15             Detected Near End Remote Loopback in
                      effect"
   ::= { dsx1AlmGrpEntry 2 }

lineStatisticalAlarmState OBJECT-TYPE
   SYNTAX     Integer32 (0..2147483647)
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This variable is a bitmap of the DSX1 Line Statistical
       Alarms. A value of zero indicates no alarms.
       Itemized below are the individual alarm bits:
       BitPosition    Alarm
       -----------    -----
       0              LCV 15 minute threshold exceeded
       1              LCV 24 hour threshold exceeded
       2              LES 15 minute threshold exceeded
       3              LES 24 hour threshold exceeded
       4              LSES 15 minute threshold exceeded
       5              LSES 24 hour threshold exceeded
       6              CRC 15 minute threshold exceeded
       7              CRC 24 hour threshold exceeded
       8              CRCES 15 minute threshold exceeded
       9              CRCES 24 hour threshold exceeded
       10             CRCSES 15 minute threshold exceeded
       11             CRCSES 24 hour threshold exceeded
       12             SEFS 15 minute threshold exceeded
       13             SEFS 24 hour threshold exceeded
       14             AISS 15 minute threshold exceeded
       15             AISS 24 hour threshold exceeded
       16             UAS 15 minute threshold exceeded
       17             UAS 24 hour threshold exceeded."
   ::= { dsx1AlmGrpEntry 3 }
lCVCurrent      OBJECT-TYPE
   SYNTAX Counter32
   MAX-ACCESS read-only
   STATUS current
   DESCRIPTION
       "This counter counts the number of
       Line code violations encountered by the interface."
   ::= { dsx1AlmGrpEntry 4 }

lCV15MinBucket  OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "The counter associated with the number of
       Line code violations in the last 15 minute period
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 5 }

lCV24HrBucket   OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "The counter associated with the number of
       Line code violations in the last 24 hour period
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 6 }

lESCurrent      OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       Line code violations Errored Seconds
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 7 }

lES15MinBucket  OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       Line code violations Errored Seconds in the last 15 minutes
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 8 }

lES24HrBucket   OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       Line code violations Errored Seconds in the last 24 hours
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 9 }

lSESCurrent     OBJECT-TYPE
   SYNTAX Counter32
   MAX-ACCESS read-only
   STATUS current
   DESCRIPTION
       "This counter counts the number of
       Line code violations Severely Errored Seconds
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 10 }

lSES15MinBucket  OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       LCV Severely Errored Seconds in the last 15 minutes
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 11 }

lSES24HrBucket  OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       LCV Severely Errored Seconds in the last 24 hours
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 12 }

cRCCurrent    OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       P Bit code violations
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 13 }

cRC15MinBucket  OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       P Bit code violations in the last 15 minutes
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 14 }

cRC24HrBucket   OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       P Bit code violations in the last 24 hours
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 15 }
cRCESCurrent      OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       PCV Errored Seconds
       encountered by the interface."
::= { dsx1AlmGrpEntry 16 }

cRCES15MinBucket  OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       PCV Errored Seconds in the last 15 minutes
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 17 }

cRCES24HrBucket   OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       PCV Errored Seconds in the last 24 hours
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 18 }

cRCSESCurrent     OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       P Bit code violations Severely Errored Seconds
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 19 }

cRCSES15MinBucket  OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       PCV Severely Errored Seconds in the last 15 minutes
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 20 }

cRCSES24HrBucket  OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       PCV Severely Errored Seconds in the last 24 hours
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 21 }

sEFSCurrent     OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       Severely Errored Framing Seconds
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 22 }

sEFS15MinBucket  OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       Severely Errored Framing Seconds in the last 15 minutes
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 23 }

sEFS24HrBucket  OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       Severely Errored Framing Seconds in the last 24 hours
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 24 }

aISSCurrent     OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       AIS Severely Errored Seconds
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 25 }

aISS15MinBucket  OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       AIS Severely Errored Seconds in the last 15 minutes
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 26 }

aISS24HrBucket  OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       AIS Severely Errored Seconds in the last 24 hours
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 27 }

uASCurrent      OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       Unavailable Seconds
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 28 }

uAS15MinBucket  OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       Unavailable Seconds in the last 15 minutes
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 29 }

uAS24HrBucket   OBJECT-TYPE
   SYNTAX     Counter32
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the number of
       Unavailable Seconds in the last 24 hours
       encountered by the interface."
   ::= { dsx1AlmGrpEntry 30 }

percentEFS      OBJECT-TYPE
   SYNTAX     Integer32(0..100)
   MAX-ACCESS read-only
   STATUS     current
   DESCRIPTION
       "This counter counts the %LCV
       Error Free Seconds."
   ::= { dsx1AlmGrpEntry 31 }

alarmClrButton OBJECT-TYPE
   SYNTAX  INTEGER {
               noaction (1),
               clear (2)
           }
   MAX-ACCESS read-write
   STATUS     current
   DESCRIPTION
       "This variable is used to clear all the alarms
       for the line.
           1 = No action
           2 = Clear alarm
       "
   ::= { dsx1AlmGrpEntry 32 }

-- conformance information

cmDsx1MIBConformance  OBJECT IDENTIFIER ::= { ciscoMgx82xxDsx1MIB 2 }

cmDsx1MIBGroups       OBJECT IDENTIFIER ::=
                             { cmDsx1MIBConformance 1 }

cmDsx1MIBCompliances  OBJECT IDENTIFIER ::=
                             { cmDsx1MIBConformance 2 }

-- compliance statements

cmDsx1Compliance MODULE-COMPLIANCE
   STATUS  current
   DESCRIPTION
       "The compliance statement for objects related
       to DS1/E1 mib."
   MODULE  -- this module
       MANDATORY-GROUPS {
           cmDsx1GeneralGroup,
           cmDsx1ConfGroup,
           cmDsx1CountGroup,
           cmDsx1AlarmConfGroup,
           cmDsx1AlarmGroup
       }
   ::= { cmDsx1MIBCompliances 1 }

cmDsx1GeneralGroup OBJECT-GROUP
   OBJECTS {
       lineNumofValidEntries
    }
    STATUS current
    DESCRIPTION
        "The collection of objects used for
        DS1/E1 interfaces."
    ::= { cmDsx1MIBGroups 1 }

cmDsx1ConfGroup OBJECT-GROUP
   OBJECTS {
       lineNum,
       lineConnectorType,
lineEnable,
lineType,
lineCoding,
      lineLength,
lineXmtClockSource,
lineLoopbackCommand,
lineSendCode,
lineLoopbackCodeDetection,
lineUsedTimeslotsBitMap,
lineBERTEnable,
lineBERTPattern,
lineBERTResult,
bERTResultClrButton
     }
     STATUS current
     DESCRIPTION
         "The collection of objects used for
         DS1/E1 interface configuration."
     ::= { cmDsx1MIBGroups 2 }

cmDsx1CountGroup OBJECT-GROUP
   OBJECTS {
       cntLineNum,
rcvLOSCount,
rcvOOFCount,
rcvRAICount,
rcvFECount,
counterClearButton
     }
   STATUS current
     DESCRIPTION
        "The collection of objects related to
        DS1/E1 statistics."
     ::= { cmDsx1MIBGroups 3 }

cmDsx1AlarmConfGroup OBJECT-GROUP
   OBJECTS {
       almCnfLineNum,
       redSeverity,
       rAISeverity,
       nEAlarmUpCount,
       nEAlarmDownCount,
       nEAlarmThreshold,
       fEAlarmUpCount,
       fEAlarmDownCount,
       fEAlarmThreshold,
       statisticalAlarmSeverity,
       lCV15MinThreshold,
       lCV24HrThreshold,
       lES15MinThreshold,
       lES24HrThreshold,
       lSES15MinThreshold,
       lSES24HrThreshold,
       cRC15MinThreshold,
       cRC24HrThreshold,
       cRCES15MinThreshold,
       cRCES24HrThreshold,
       cRCSES15MinThreshold,
       cRCSES24HrThreshold,
       sEFS15MinThreshold,
       sEFS24HrThreshold,
       aISS15MinThreshold,
       aISS24HrThreshold,
       uAS15MinThreshold,
       uAS24HrThreshold
      }
   STATUS current
   DESCRIPTION
       "The collection of objects used for
        DS1/E1 Alarm threshold configuration."
     ::= { cmDsx1MIBGroups 4 }

cmDsx1AlarmGroup OBJECT-GROUP
   OBJECTS {
       almLineNum,
       lineAlarmState,
       lineStatisticalAlarmState,
       lCVCurrent,
       lCV15MinBucket,
       lCV24HrBucket,
       lESCurrent,
       lES15MinBucket,
       lES24HrBucket,
       lSESCurrent,
       lSES15MinBucket,
       lSES24HrBucket,
       cRCCurrent,
       cRC15MinBucket,
       cRC24HrBucket,
       cRCESCurrent,
       cRCES15MinBucket,
       cRCES24HrBucket,
       cRCSESCurrent,
       cRCSES15MinBucket,
       cRCSES24HrBucket,
       sEFSCurrent,
       sEFS15MinBucket,
       sEFS24HrBucket,
       aISSCurrent,
       aISS15MinBucket,
       aISS24HrBucket,
       uASCurrent,
       uAS15MinBucket,
       uAS24HrBucket,
       percentEFS,
       alarmClrButton
}
    STATUS current
    DESCRIPTION
        "The collection of objects used for
        DS1/E1 Alarm configuration."
    ::= { cmDsx1MIBGroups 5 }

END