This management information module supports the configuration and management of SONET linear APS groups. The definitions and descriptions used in this mib have been derived from Synchronous Optical Network (SONET) Transport Systems: Common Generic Crit...

-- *********************************************************************
-- CISCO-APS-MIB.my: Cisco Automatic Protection Switching (APS) MIB
--
-- April 2001, Ashok Chippa, Altaf Shaikh
--
-- Copyright (c) 2001 by Cisco Systems, Inc.
-- All rights reserved.
--
-- *********************************************************************
--

  CISCO-APS-MIB DEFINITIONS ::= BEGIN

  IMPORTS
       MODULE-IDENTITY, NOTIFICATION-TYPE,
       OBJECT-TYPE,
       Gauge32, Counter32, Integer32
         FROM SNMPv2-SMI

       TEXTUAL-CONVENTION, RowStatus, TimeStamp
         FROM SNMPv2-TC

       SnmpAdminString
         FROM SNMP-FRAMEWORK-MIB

       InterfaceIndex
         FROM IF-MIB

       ciscoExperiment
         FROM CISCO-SMI

       MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
         FROM SNMPv2-CONF;

  cApsMIB MODULE-IDENTITY
      LAST-UPDATED    "200104290000Z"
      ORGANIZATION    "Cisco Systems, Inc."
      CONTACT-INFO    "Cisco Systems, Inc.
                       Customer Service
                       Postal: 170 W. Tasman Drive
                               San Jose, CA  95134-1706
                               USA
                       Tel: +1 800 553-NETS
                       Email: optmgmt-dev@cisco.com"


      DESCRIPTION
      "This management information module supports the configuration
       and management of SONET linear APS groups. The definitions and
       descriptions used in this mib have been derived from
       Synchronous Optical Network (SONET) Transport Systems: Common
       Generic Criteria, GR-253-CORE Revision 2, January 1999,
       section 5.3. The MIB is also consistent with the Multiplex
       Section Protection (MSP) protocol as specified in ITU-T
       Recommendation G.783, Characteristics of synchronous digital
       hierarchy (SDH) equipment function blocks, Annex A and B.

       This MIB was extracted from internet draft
       draft-ietf-atommib-sonetaps-mib-04.txt for SONET Linear APS
       architectures, by J. Johnson, M. Thatcher, and J. Kuhfeld.
       The objects modified in this MIB implementation from that in
       the draft are cApsConfigCreationTime and
       cApsChanStatusLastSwitchover. They are defined as TimeTicks in
       the draft and have been changed to TimeStamp in this MIB.
      "

      REVISION      "200104290000Z"
      DESCRIPTION
      "A draft version of the APS MIB.
      "
      ::= { ciscoExperiment 71 }

  cApsMIBObjects OBJECT IDENTIFIER
      ::= { cApsMIB 1 }

  cApsMIBNotifications OBJECT IDENTIFIER
      ::= { cApsMIB 2 }

  cApsMIBConformance OBJECT IDENTIFIER
      ::= { cApsMIB 3 }

  CApsK1K2 ::= TEXTUAL-CONVENTION
      STATUS current
      DESCRIPTION
      "This Textual Convention describes an object that stores
       a SONET K1 and K2 byte APS protocol field.

       K1 is located in the first octet, K2 is located in
       the second octet. Bits are numbered from left to right.

       Bits 1-4 of the K1 byte indicate a request.

       1111  Lockout of Protection
       1110  Forced Switch
       1101  SF - High Priority
       1100  SF - Low Priority
       1011  SD - High Priority
       1010  SD - Low Priority
       1001  not used
       1000  Manual Switch
       0111  not used
       0110  Wait-to-Restore
       0101  not used
       0100  Exercise
       0011  not used
       0010  Reverse Request
       0001  Do Not Revert
       0000  No Request

       Bits 5-8 of the K1 byte indicate the channel associated with the
       request defined in bits 1-4.

       0000 is the Null channel.

       1-14 are working channels.
       15   is the extra traffic channel

       Bits 1-4 of the K2 byte indicate a channel. The channel is
       defined with the same syntax as K1 Bits 5-8.


       Bit 5 of the K2 byte indicates the
       architecture.

       0 if the architecture is 1+1
       1 if the architecture is 1:n

       Bits 6-8 of the K2 byte indicates the
       mode.

       000 - 011 are reserved for future use

       100  indicates the mode is unidirectional
       101  indicates the mode is bidirectional

       110  RDI-L

       111  AIS-L
      "
      REFERENCE
          "Bellcore (Telcordia Technologies) GR-253-CORE, Issue 2,
           Revision 2 (January 1999), 5.3.5."
      SYNTAX      OCTET STRING (SIZE (2))


  CApsSwitchCommand ::= TEXTUAL-CONVENTION
      STATUS       current
      DESCRIPTION
      "An APS switch command allows a user to perform protection
       switch actions.

       The Switch command values are:

       noCmd

       This value should be returned by a read request when no switch
       command has been written to the object in question since
       initialization. This value may not be used in a write operation.

       clear

       Clears all of the switch commands listed below for the specified
       channel.

       lockoutOfProtection

       Prevents any of the working channels from switching to the
       protection line. The specified channel should be the
       protection channel.

       forcedSwitchWorkToProtect

       Switches the specified working channel to the protection line.

       forcedSwitchProtectToWork

       Switches the working channel back from the protection
       line to the working line. The specified channel should be
       the protection channel.

       manualSwitchWorkToProtect

       Switches the specified working channel to the protection line.

       manualSwitchProtectToWork

       Switches the working channel back from the protection
       line to the working line. The specified channel should be
       the protection channel.

       exercise

       Exercises the protocol for a protection switch of the specified
       channel by issuing an Exercise request for that channel and
       checking the response on the APS channel.
      "
      SYNTAX       INTEGER {
                       noCmd(1),
                       clear(2),
                       lockoutOfProtection(3),
                       forcedSwitchWorkToProtect(4),
                       forcedSwitchProtectToWork(5),
                       manualSwitchWorkToProtect(6),
                       manualSwitchProtectToWork(7),
                       exercise(8)
                   }

  CApsControlCommand ::= TEXTUAL-CONVENTION
      STATUS       current
      DESCRIPTION
      "An APS control command applies only to LTE that support the
       1:n architecture and performs the following actions.


       The Control command values are:

       noCmd

       This value should be returned by a read request when no control
       command has been written to the object in question since
       initialization. This value may not be used in a write operation.

       lockoutWorkingChannel

       Prevents the specified working channel from switching to the
       protection line.

       clearLockoutWorkingChannel

       Clears the lockout a working channel command for the channel
       specified.
      "
      SYNTAX       INTEGER {
                       noCmd(1),
                       lockoutWorkingChannel(2),
                       clearLockoutWorkingChannel(3)
                   }


  --
  -- APS Configuration Table
  --
  -- This table supports the addition, configuration and deletion of
  -- APS groups.
  --

  cApsConfig     OBJECT IDENTIFIER ::= { cApsMIBObjects 1 }

  cApsConfigGroups OBJECT-TYPE
      SYNTAX      Gauge32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
      "The count of APS groups. This count includes all rows in
       cApsConfigTable."
      ::= { cApsConfig 1 }


  cApsConfigTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF CApsConfigEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
      "This table lists the APS groups that have been configured
       on the system."
      ::= { cApsConfig 2 }

  cApsConfigEntry OBJECT-TYPE
      SYNTAX      CApsConfigEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
      "A conceptual row in the cApsConfigTable.
      "
      INDEX { IMPLIED cApsConfigName }
      ::= { cApsConfigTable  1 }

  CApsConfigEntry ::= SEQUENCE {
      cApsConfigName                  SnmpAdminString,
      cApsConfigRowStatus             RowStatus,
      cApsConfigMode                  INTEGER,
      cApsConfigRevert                INTEGER,
      cApsConfigDirection             INTEGER,
      cApsConfigExtraTraffic          INTEGER,
      cApsConfigSdBerThreshold        Integer32,
      cApsConfigSfBerThreshold        Integer32,
      cApsConfigWaitToRestore         Integer32,
      cApsConfigCreationTime          TimeStamp
  }


  cApsConfigName OBJECT-TYPE
      SYNTAX      SnmpAdminString (SIZE (1..32))
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
      "A textual name for the APS group.
      "
      ::= { cApsConfigEntry 1 }

  cApsConfigRowStatus OBJECT-TYPE
      SYNTAX      RowStatus
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
      "The status of this APS group entry.

       An entry may not exist in the active state unless all
       objects in the entry have an appropriate value. Also,
       all associated cApsChanConfigEntry rows must represent
       a set of consecutive channel numbers beginning with
       0 or 1, depending on the selected architecture.

       When set to notInService changes may be made to
       cApsConfigMode, cApsConfigRevert, cApsConfigDirection,
       cApsConfigExtraTraffic, cApsConfigSdBerThreshold,
       cApsConfigSfBerThreshold, and cApsConfigWaitToRestore.
       Also, associated cApsChanConfigTable objects may be added,
       deleted and modified.
      "
      ::= { cApsConfigEntry 2 }

  cApsConfigMode OBJECT-TYPE
      SYNTAX      INTEGER {
                          onePlusOne(1),
                          oneToN(2),
                          onePlusOneCompatible(3),
                          onePlusOneOptimized(4)
                          }
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
      "The architecture of the APS group.

       onePlusOne

       The 1+1 architecture permanently bridges the working
       line to the protection line.

       oneToN

       The 1:n architecture allows one protection channel to
       protect up to n working channels. When a fault is detected
       on one of the n working channels that channel is bridged
       over the protection channel.

       onePlusOneCompatible

       This refers to 1 + 1 bidirectional switching compatible with
       1:n bidirectional switching as specified in ITU-T
       Recommendation G.783 (04/97) section A.3.4.1. Since this
       mode necessitates bidirectional switching,
       cApsConfigDirection must be set to bidirectional whenever
       onePlusOneCompatible is set.

       onePlusOneOptimized

       This refers to 1 + 1 bidirectional switching optimized
       for a network using predominantly 1 + 1 bidirectional
       switching as specified in ITU-T Recommendation G.783 (04/97)
       section B.1. Since this mode necessitates bidirectional
       switching, cApsConfigDirection must be set to bidirectional
       whenever onePlusOneOptimized is set.

       This object may not be modified if the associated
       cApsConfigRowStatus object is equal to active(1).
      "
      DEFVAL {onePlusOne}
      ::= { cApsConfigEntry 3 }

  cApsConfigRevert OBJECT-TYPE
      SYNTAX      INTEGER { nonrevertive(1), revertive(2) }
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
      "The revertive mode of the APS group.

       nonrevertive

       Traffic remains on the protection line until another switch
       request is received.

       revertive

       When the condition that caused a switch to the protection
       line has been cleared the signal is switched back to the
       working line. Since switching is revertive with the 1:n
       architecture, cApsConfigRevert must be set to revertive if
       cApsConfigMode is set to oneToN.

       Switching may optionally be revertive with the 1+1
       architecture.

       This object may not be modified if the associated
       cApsConfigRowStatus object is equal to active(1).
      "
      DEFVAL { nonrevertive }
      ::= { cApsConfigEntry 4 }


  cApsConfigDirection OBJECT-TYPE
      SYNTAX      INTEGER { unidirectional(1), bidirectional(2) }
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
      "The directional mode of the APS group.

       unidirectional

       The unidirectional mode provides protection in one direction.

       bidirectional

       The bidirectional mode provides protection in both
       directions.

       This object may not be modified if the associated
       cApsConfigRowStatus object is equal to active(1).
      "
      DEFVAL {unidirectional}
      ::= { cApsConfigEntry 5 }


  cApsConfigExtraTraffic OBJECT-TYPE
      SYNTAX      INTEGER { enabled(1), disabled(2) }
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
      "This object enables or disables the transfer of extra traffic
       on the protection channel in a 1:n architecture. This object
       must be set to disabled if the architecture is 1+1. It may be
       necessary to disable this in order to interwork with other
       SONET network elements that don't support extra traffic.

       This object may not be modified if the associated
       cApsConfigRowStatus object is equal to active(1).
      "
      DEFVAL { disabled }
      ::= { cApsConfigEntry 6 }


  cApsConfigSdBerThreshold OBJECT-TYPE
      SYNTAX      Integer32 (5..9)
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
      "The Signal Degrade Bit Error Rate.

       The negated value of this number is used as the exponent of
       10 for computing the threshold value for the Bit Error Rate
       (BER). For example, a value of 5 indicates a BER threshold
       of 10^-5.

       This object may be modified if the associated
       cApsConfigRowStatus object is equal to active(1).
      "
      DEFVAL { 5 }
      ::= { cApsConfigEntry 7 }


  cApsConfigSfBerThreshold OBJECT-TYPE
      SYNTAX      Integer32 (3..5)
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
      "The Signal Failure Bit Error Rate.

       The negated value of this number is used as the exponent of
       10 for computing the threshold value for the Bit Error Rate
       (BER). For example, a value of 5 indicates a BER threshold
       of 10^-5.

       This object may be modified if the associated
       cApsConfigRowStatus object is equal to active(1).
      "
      DEFVAL { 3 }
      ::= { cApsConfigEntry 8 }

  cApsConfigWaitToRestore OBJECT-TYPE
      SYNTAX      Integer32 (0..720)
      UNITS       "seconds"
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
      "The Wait To Restore period in seconds.

       After clearing of a condition that necessitated an
       automatic switch, the wait to restore period must elapse
       before reverting. This is intended to avoid rapid switch
       oscillations.

       GR-253-CORE specifies a Wait To Restore range of 5 to 12
       minutes. G.783 defines a 5 to 12 minute Wait To Restore
       range in section 5.4.1.1.3, but also allows for a shorter
       WTR period in  Table 2-1,
       WaitToRestore value (MI_WTRtime: 0..(5)..12 minutes).

       This object may not be modified if the associated
       cApsConfigRowStatus object is equal to active(1).
      "
      DEFVAL { 300 }
      ::= { cApsConfigEntry 9 }

  cApsConfigCreationTime OBJECT-TYPE
      SYNTAX      TimeStamp
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
      "The value of sysUpTime at the time the row was created.
      "
      ::= { cApsConfigEntry 10 }


  --
  -- APS Status Table
  --
  -- This table provides APS group statistics.
  --


  cApsStatusTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF CApsStatusEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
      "This table provides status information about APS groups
       that have been configured on the system.
      "
      ::= { cApsMIBObjects 2 }

  cApsStatusEntry OBJECT-TYPE
      SYNTAX      CApsStatusEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
      "A conceptual row in the cApsStatusTable. Entries in this table
       are created as a side effect of row addition in cApsConfigTable.
      "
      INDEX { IMPLIED cApsConfigName}
      ::= { cApsStatusTable  1 }

  CApsStatusEntry ::= SEQUENCE {
      cApsStatusK1K2Rcv               CApsK1K2,
      cApsStatusK1K2Trans             CApsK1K2,
      cApsStatusCurrent               BITS,
      cApsStatusModeMismatches        Counter32,
      cApsStatusChannelMismatches     Counter32,
      cApsStatusPSBFs                 Counter32,
      cApsStatusFEPLFs                Counter32,
      cApsStatusSwitchedChannel       Integer32
  }


  cApsStatusK1K2Rcv OBJECT-TYPE
      SYNTAX      CApsK1K2
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
      "The current value of the K1 and K2 bytes received on the
       protection channel.
      "
      ::= { cApsStatusEntry 1 }


  cApsStatusK1K2Trans OBJECT-TYPE
      SYNTAX        CApsK1K2
      MAX-ACCESS    read-only
      STATUS        current
      DESCRIPTION
      "The current value of the K1 and K2 bytes transmitted on the
       protection channel.
      "
      ::= { cApsStatusEntry 2 }



  cApsStatusCurrent OBJECT-TYPE
      SYNTAX      BITS {
                    modeMismatch(0),
                    channelMismatch(1),
                    psbf(2),
                    feplf(3),
                    extraTraffic(4)
                   }
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
      "The current status of the APS group.

       modeMismatch

       Modes other than 1+1 unidirectional monitor protection line
       K2 bit 5, which indicates the architecture and K2 bits
       6-8, which indicate if the mode is unidirectional or
       bidirectional. A conflict between the current local mode
       and the received K2 mode information constitutes a
       mode mismatch.

       channelMismatch

       This bit indicates a  mismatch between the transmitted K1
       channel and the received K2 channel has been detected.

       psbf

       This bit indicates a Protection Switch Byte Failure (PSBF) is
       in effect. This condition occurs when either an inconsistent
       APS byte or an invalid code is detected. An inconsistent APS
       byte occurs when no three consecutive K1 bytes of the last 12
       successive frames are identical, starting with the last frame
       containing a previously consistent byte. An invalid code occurs
       when the incoming K1 byte contains an unused code or a code
       irrelevant for the specific switching operation (e.g., Reverse
       Request while no switching request is outstanding) in three
       consecutive frames. An invalid code also occurs when the
       incoming K1 byte contains an invalid channel number in three
       consecutive frames.

       feplf

       Modes other than 1+1 unidirectional monitor the K1 byte
       for Far-End Protection-Line failures. A Far-End
       Protection-Line defect is declared based on receiving
       SF on the protection line.

       extraTraffic

       This bit indicates whether extra traffic is currently being
       accepted on the protection line.
      "
      ::= { cApsStatusEntry 3 }


  cApsStatusModeMismatches OBJECT-TYPE
      SYNTAX     Counter32
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
      "A count of Mode Mismatch conditions.
      "
      ::= { cApsStatusEntry 4 }


  cApsStatusChannelMismatches OBJECT-TYPE
      SYNTAX     Counter32
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
      "A count of Channel Mismatch conditions.
      "
      ::= { cApsStatusEntry 5 }

  cApsStatusPSBFs OBJECT-TYPE
      SYNTAX     Counter32
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
      "A count of Protection Switch Byte Failure conditions.
       This condition occurs when either an inconsistent APS
       byte or an invalid code is detected. An inconsistent APS
       byte occurs when no three consecutive K1 bytes of the last
       12 successive frames are identical, starting with the last
       frame containing a previously consistent byte. An invalid
       code occurs when the incoming K1 byte contains an unused
       code or a code irrelevant for the specific switching
       operation (e.g., Reverse Request while no switching
       request is outstanding) in three consecutive frames.
       An invalid code also occurs when the incoming K1 byte
       contains an invalid channel number in three consecutive
       frames.
      "
      ::= { cApsStatusEntry 6 }

  cApsStatusFEPLFs OBJECT-TYPE
      SYNTAX     Counter32
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
      "A count of Far-End Protection-Line Failure conditions.
       This condition is declared based on receiving SF on
       the protection line in the K1 byte.
      "
      ::= { cApsStatusEntry 7 }

  cApsStatusSwitchedChannel OBJECT-TYPE
      SYNTAX     Integer32
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
      "This field is set to the number of the channel that is
       currently switched to protection. The value 0 indicates no
       channel is switched to protection. The values 1-14 indicate
       that working channel is switched to protection.
      "
      ::= { cApsStatusEntry 8 }


  --
  -- APS Map Group
  --
  -- Lists the SONET LTE interfaces that may be used to create APS
  -- groups.
  --

  cApsMap      OBJECT IDENTIFIER ::= { cApsMIBObjects 3 }

  cApsChanLTEs OBJECT-TYPE
      SYNTAX      Gauge32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
      "The count of SONET LTE interfaces on the system. Each
       interface that is included has an ifType value of sonet(39).
      "
      ::= { cApsMap 1 }


  cApsMapTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF CApsMapEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
      "This table lists the SONET LTE interfaces on the system. Each
       interface that is listed has an ifType value of sonet(39).
      "
      ::= { cApsMap 2 }

  cApsMapEntry OBJECT-TYPE
      SYNTAX      CApsMapEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
      "A conceptual row in the cApsMapTable.
      "
      INDEX { cApsMapIfIndex }
      ::= { cApsMapTable  1 }

  CApsMapEntry ::= SEQUENCE {
      cApsMapIfIndex               InterfaceIndex,
      cApsMapGroupName             SnmpAdminString,
      cApsMapChanNumber            Integer32
  }


  cApsMapIfIndex OBJECT-TYPE
      SYNTAX     InterfaceIndex
      MAX-ACCESS not-accessible
      STATUS     current
      DESCRIPTION
      "The Interface Index assigned to a SONET LTE. This is an
       interface with ifType sonet(39).
      "
      ::= { cApsMapEntry 1 }


  cApsMapGroupName OBJECT-TYPE
      SYNTAX      SnmpAdminString (SIZE (0..32))
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
      "A textual name for the APS group which this channel is
       included in. If the channel is not part of an APS group
       this value is set to a string of size 0.

       When an instance of cApsChanConfigIfIndex is set equal to an
       instance of cApsMapIfIndex, cApsMapGroupName is set equal
       to the corresponding value of cApsChanConfigGroupName.

       If the cApsMapIfIndex ceases to be equal to an instance of
       cApsChanConfigIfIndex, either because of a change in the
       value of cApsChanConfigIfIndex, or because of row deletion
       in the CApsChanConfigTable, cApsMapGroupName is set to a
       string of size 0.
      "
      ::= { cApsMapEntry 2 }


  cApsMapChanNumber OBJECT-TYPE
      SYNTAX     Integer32 (-1..14)
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
      "This field is set to a unique channel number within an APS
       group. The value 0 indicates the null channel. The values 1-14
       define a working channel. If the SONET LTE is not part of an
       APS group this value is set to -1.

       When an instance of cApsChanConfigIfIndex is set equal to an
       instance of cApsMapIfIndex, cApsMapChanNumber is set equal to
       the corresponding value of cApsChanConfigNumber.

       If the cApsMapIfIndex ceases to be equal to an instance of
       cApsChanConfigIfIndex, either because of a change in the value
       of cApsChanConfigIfIndex, or because of row deletion in the
       CApsChanConfigTable, cApsMapChanNumber is set to -1.
      "
      ::= { cApsMapEntry 3 }

  --
  -- APS Channel Configuration Table
  --
  -- This table supports the addition, configuration and deletion of
  -- channels in APS groups.
  --


  cApsChanConfigTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF CApsChanConfigEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
      "This table lists the APS channels that have been configured
       in APS groups.
      "
      ::= { cApsMIBObjects 4 }

  cApsChanConfigEntry OBJECT-TYPE
      SYNTAX      CApsChanConfigEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
      "A conceptual row in the cApsChanConfigTable.
      "
      INDEX {cApsChanConfigGroupName, cApsChanConfigNumber}
      ::= { cApsChanConfigTable  1 }

  CApsChanConfigEntry ::= SEQUENCE {
      cApsChanConfigGroupName             SnmpAdminString,
      cApsChanConfigNumber                Integer32,
      cApsChanConfigRowStatus             RowStatus,
      cApsChanConfigIfIndex               InterfaceIndex,
      cApsChanConfigPriority              INTEGER
  }

  cApsChanConfigGroupName OBJECT-TYPE
      SYNTAX      SnmpAdminString (SIZE (1..32))
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
      "A textual name for the APS group which this channel is
       included in.
      "
      ::= { cApsChanConfigEntry 1 }

  cApsChanConfigNumber OBJECT-TYPE
      SYNTAX     Integer32 (0..14)
      MAX-ACCESS not-accessible
      STATUS     current
      DESCRIPTION
      "This field is set to a unique channel number within an APS
       group. The value 0 indicates the null channel. The values 1-14
       define a working channel.

       This field must be assigned a unique number within the group.
      "
      ::= { cApsChanConfigEntry 2 }

  cApsChanConfigRowStatus OBJECT-TYPE
      SYNTAX      RowStatus
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
      "The status of this APS channel entry.

       An entry may not exist in the active state unless all
       objects in the entry have an appropriate value.

       A row in the cApsChanConfigTable may not be created,
       deleted, set to notInService or otherwise modified
       if the cApsChanConfigGroupName value is equal to an
       cApsConfigName value and the associated cApsConfigRowStatus
       object is equal to active. However, if the
       cApsConfigRowStatus object is equal to notInService, a row
       may be created, deleted or modified. In other words, a
       channel may not be added, deleted or modified if the group
       is active.

       A row may be created with an cApsChanConfigGroupName value
       that is not equal to any existing instance of cApsConfigName.
       This action is the initial step in adding a SONET LTE to a
       new APS group.

       If this object is set to destroy, the associated instance
       of cApsMapGroupName will be set to a string of size 0 and
       the cApsMapChanNumber will be set to -1. The channel status
       entry will also be deleted by this action.

       cApsChanConfigNumber must be set to a unique channel number
       within the APS group. The value 0 indicates the null channel.
       The values 1-14 define a working channel. When an attempt is
       made to set the  corresponding cApsConfigRowStatus field to
       active the cApsChanConfigNumber values of all entries with
       equal cApsChanConfigGroupName fields must represent a set of
       consecutive integer values beginning with 0 or 1, depending
       on the architecture of the group, and ending with n, where
       n is  greater than or equal to 1 and less than or equal to
       14. Otherwise, the error inconsistentValue is returned to
       the cApsConfigRowStatus set attempt.
      "
      ::= { cApsChanConfigEntry 3 }

  cApsChanConfigIfIndex OBJECT-TYPE
      SYNTAX     InterfaceIndex
      MAX-ACCESS read-create
      STATUS     current
      DESCRIPTION
      "The Interface Index assigned to a SONET LTE. This is an
       interface with ifType sonet(39). The value of this object
       must be unique among all instances of cApsChanConfigIfIndex.
       In other words, a particular SONET LTE can only be configured in
       one APS group.

       This object cannot be set if the cApsChanConfigGroupName
       instance associated with this row is equal to an instance of
       cApsConfigName and the corresponding cApsConfigRowStatus object
       is set to active. In other words this value cannot be changed
       if the APS group is active. However, this value may be changed
       if the cApsConfigRowStatus value is equal to notInService.
      "
      ::= { cApsChanConfigEntry 4 }


  cApsChanConfigPriority OBJECT-TYPE
      SYNTAX     INTEGER {low(1), high(2)}
      MAX-ACCESS read-create
      STATUS     current
      DESCRIPTION
      "The priority of the channel.

       This field deterimines whether high or low priority
       SD and SF codes are used in K1 requests.

       This field is only applicable if the channel is to be
       included in a group using the 1:n architecture. It is not
       applicable if the channel is to be included in a group
       using the 1+1 architecture, and is ignored in that case.

       This object cannot be set if the cApsChanConfigGroupName
       instance associated with this row is equal to an instance
       of cApsConfigName and the corresponding cApsConfigRowStatus
       object is set to active. In other words this value cannot
       be changed if the APS group is active. However, This value
       may be changed if the cApsConfigRowStatus value is equal to
       notInService.
      "
      DEFVAL { low }
      ::= { cApsChanConfigEntry 5 }


  --
  -- APS Command Table
  --
  -- This table provides the ability to initiate APS commands.
  --

  cApsCommandTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF CApsCommandEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
      "This table allows commands to be sent to configured APS
       groups.
      "
      ::= { cApsMIBObjects 5 }

  cApsCommandEntry OBJECT-TYPE
      SYNTAX      CApsCommandEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
      "A conceptual row in the cApsCommandTable. This row exists
       only if the associated cApsConfigEntry is active.
      "
      INDEX {cApsChanConfigGroupName, cApsChanConfigNumber}
      ::= { cApsCommandTable  1 }

  CApsCommandEntry ::= SEQUENCE {
      cApsCommandSwitch         CApsSwitchCommand,
      cApsCommandControl        CApsControlCommand
  }

  cApsCommandSwitch OBJECT-TYPE
      SYNTAX      CApsSwitchCommand
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
      "Allows the initiation of an APS switch command on the
       APS group and channel specified by the index values.

       When read this object returns the last command written
       or noCmd if no command has been written to this
       channel since initialization. The return of the last command
       written does not imply that this command is currently in effect.
       This request may have been preempted by a higer priority
       local or remote request. In order to determine the
       current state of the APS group it is necessary to read
       the objects cApsStatusK1K2Rcv and cApsStatusK1K2Trans.

       The value lockoutOfProtection should only be applied
       to the protection line channel since that switch command
       prevents any of the working channels from switching to the
       protection line. Following the same logic,
       forcedSwitchProtectToWork and manualSwitchProtectToWork should
       only be applied to the protection line channel.

       forcedSwitchWorkToProtect and manualSwitchWorkToProtect
       should only be applied to a working channel.
      "
      ::= { cApsCommandEntry 1 }

  cApsCommandControl OBJECT-TYPE
      SYNTAX      CApsControlCommand
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
      "Allows the initiation of an APS control command on the
       APS group and channel specified by the index values.

       When read this object returns the last command written
       or noCmd if no command has been
       written to this channel since initialization.

       This object does not apply to the protection line.
      "
      ::= { cApsCommandEntry 2 }

  --
  -- APS Channel Status Table
  --
  -- This table provides APS channel statistics.
  --

  cApsChanStatusTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF CApsChanStatusEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
      "This table contains status information for all SONET LTE
       interfaces that are included in APS groups.
      "
      ::= { cApsMIBObjects 6 }

  cApsChanStatusEntry OBJECT-TYPE
      SYNTAX      CApsChanStatusEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
      "A conceptual row in the cApsChanStatusTable. A row in this
       table is created as a side effect of row addition in the
       cApsChanConfigTable. The cApsChanStatusTable row exists
       as long as the cApsChanConfigTable entry exists, regardless
       of whether the associated cApsChanConfigRowStatus is active.
      "
      INDEX {cApsChanConfigGroupName, cApsChanConfigNumber}
      ::= { cApsChanStatusTable  1 }

  CApsChanStatusEntry ::= SEQUENCE {
      cApsChanStatusCurrent               BITS,
      cApsChanStatusSignalDegrades        Counter32,
      cApsChanStatusSignalFailures        Counter32,
      cApsChanStatusSwitchovers           Counter32,
      cApsChanStatusLastSwitchover        TimeStamp
  }

  cApsChanStatusCurrent OBJECT-TYPE
      SYNTAX     BITS {
                 lockedOut(0),
                 sd(1),
                 sf(2),
                 switched(3)
              }
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
      "Indicates the current state of the port.

       lockedOut

       This bit, when applied to a working channel, indicates that
       the channel is prevented from switching to the protection
       line. When applied to the null channel, this bit indicates
       that no working channel may switch to the protection line.

       sd

       A signal degrade condition is in effect.

       sf

       A signal failure condition is in effect.

       switched

       The switched bit is applied to a working channel if that
       channel is currently switched to the protection line.
      "
      ::= { cApsChanStatusEntry 1 }


  cApsChanStatusSignalDegrades OBJECT-TYPE
      SYNTAX     Counter32
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
      "A count of Signal Degrade conditions. This condition occurs
       when the line Bit Error Rate exceeds the currently configured
       threshold.
      "
          ::= { cApsChanStatusEntry 2 }

  cApsChanStatusSignalFailures OBJECT-TYPE
      SYNTAX     Counter32
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
      "A count of Signal Failure conditions that have been detected on
       the incoming signal. This condition occurs when a loss of
       signal, loss of frame, AIS-L or a Line bit error rate exceeding
       10^-3 is detected on an incoming line.
      "
      ::= { cApsChanStatusEntry 3 }

  cApsChanStatusSwitchovers OBJECT-TYPE
      SYNTAX     Counter32
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
      "The number of times this channel has switched to the protection
       line. When queried with index value cApsChanConfigNumber set to
       0, which is the protection line, this object will return 0.
      "
      ::= { cApsChanStatusEntry 4 }

  cApsChanStatusLastSwitchover OBJECT-TYPE
      SYNTAX     TimeStamp
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
      "The value of sysUpTime when this channel last completed a
       switch to the protection line. If this channel has never
       switched to the protection line, or this channel is the
       protection line, the value 0  will be returned.
      "
      ::= { cApsChanStatusEntry 5 }

  --
  -- APS EVENTS
  --

  cApsNotificationsPrefix OBJECT IDENTIFIER
       ::= { cApsMIBNotifications 0 }

  cApsEventSwitchover NOTIFICATION-TYPE
      OBJECTS { cApsChanStatusSwitchovers, cApsChanStatusCurrent }
      STATUS  current
      DESCRIPTION
      "A cApsEventSwitchover notification is sent when the
       value of an instance of cApsChanStatusSwitchovers increments.
      "
      ::= { cApsNotificationsPrefix 1 }

  cApsEventModeMismatch NOTIFICATION-TYPE
      OBJECTS { cApsStatusModeMismatches, cApsStatusCurrent }
      STATUS  current
      DESCRIPTION
      "A cApsEventModeMismatch notification is sent when the value of
       an instance of cApsStatusModeMismatches increments.
      "
      ::= { cApsNotificationsPrefix 2 }

  cApsEventChannelMismatch NOTIFICATION-TYPE
      OBJECTS { cApsStatusChannelMismatches, cApsStatusCurrent }
      STATUS  current
      DESCRIPTION
      "A cApsEventChannelMismatch notification is sent when the value
       of an instance of cApsStatusChannelMismatches increments.
      "
      ::= { cApsNotificationsPrefix 3 }

  cApsEventPSBF NOTIFICATION-TYPE
      OBJECTS { cApsStatusPSBFs, cApsStatusCurrent }
      STATUS  current
      DESCRIPTION
      "An cApsEventPSBF notification is sent when the value of an
       instance of cApsStatusPSBFs increments.
      "
      ::= { cApsNotificationsPrefix 4 }

  cApsEventFEPLF NOTIFICATION-TYPE
      OBJECTS { cApsStatusFEPLFs, cApsStatusCurrent }
      STATUS  current
      DESCRIPTION
      "An cApsEventFEPLFs notification is sent when the value of an
       instance of cApsStatusFEPLFs increments.
      "
      ::= { cApsNotificationsPrefix 5 }


  -- conformance information

  cApsGroups      OBJECT IDENTIFIER ::= { cApsMIBConformance 1 }
  cApsCompliances OBJECT IDENTIFIER ::= { cApsMIBConformance 2 }

  cApsCompliance MODULE-COMPLIANCE
      STATUS  current
      DESCRIPTION
      "The compliance statement for linear APS groups.
      "

      MODULE
      MANDATORY-GROUPS { cApsConfigGeneral,
                         cApsStatusGeneral,
                         cApsChanGeneral }

          OBJECT  cApsConfigMode
          MIN-ACCESS  read-only
          DESCRIPTION
              "Write access is not required."

          OBJECT  cApsConfigRevert
          MIN-ACCESS  read-only
          DESCRIPTION
              "Write access is not required."

          OBJECT  cApsConfigDirection
          MIN-ACCESS  read-only
          DESCRIPTION
              "Write access is not required."

          OBJECT  cApsConfigExtraTraffic
          MIN-ACCESS  read-only
          DESCRIPTION
              "Write access is not required."

          OBJECT  cApsConfigSdBerThreshold
          MIN-ACCESS  read-only
          DESCRIPTION
              "Write access is not required."

          OBJECT  cApsConfigSfBerThreshold
          MIN-ACCESS  read-only
          DESCRIPTION
              "Write access is not required."

          OBJECT  cApsConfigWaitToRestore
          MIN-ACCESS  read-only
          DESCRIPTION
              "Write access is not required."

          OBJECT  cApsConfigRowStatus
          MIN-ACCESS  read-only
          DESCRIPTION
              "Write access is not required."

          OBJECT  cApsChanConfigIfIndex
          MIN-ACCESS  read-only
          DESCRIPTION
              "Write access is not required."

          OBJECT  cApsChanConfigPriority
          MIN-ACCESS  read-only
          DESCRIPTION
              "Write access is not required."

          OBJECT  cApsChanConfigRowStatus
          MIN-ACCESS  read-only
          DESCRIPTION
              "Write access is not required."

          GROUP       cApsConfigWtr
          DESCRIPTION
              "Implementation of this group is optional for all
               linear APS implementations. The information is
               applicable to groups supporting a configurable
               WTR period."

          GROUP       cApsCommandOnePlusOne
          DESCRIPTION
              "Implementation of this group is optional for all
               linear APS implementations. The information is
               applicable to groups implementing the linear
               APS 1+1 architecture and supporting set operations."

         GROUP       cApsCommandOneToN
          DESCRIPTION
              "Implementation of this group is optional for all
               linear APS implementations. The information is
               applicable to groups implementing the linear
               APS 1:n architecture and supporting set operations."

         GROUP       cApsChanOneToN
          DESCRIPTION
              "Implementation of this group is optional for all
               linear APS implementations. The information is
               applicable to groups implementing the linear
               APS 1:n architecture."

         GROUP       cApsTotalsGroup
          DESCRIPTION
              "Implementation of this group is optional for all
               linear APS implementations."

         GROUP       cApsMapGroup
          DESCRIPTION
              "Implementation of this group is optional for all
               linear APS implementations."

      ::= { cApsCompliances 1 }

  -- units of conformance

  cApsConfigGeneral    OBJECT-GROUP
      OBJECTS
      {
          cApsConfigMode,
          cApsConfigRevert,
          cApsConfigDirection,
          cApsConfigExtraTraffic,
          cApsConfigSdBerThreshold,
          cApsConfigSfBerThreshold,
          cApsConfigCreationTime,
          cApsConfigRowStatus
      }
      STATUS  current
      DESCRIPTION
      "A collection of cApsConfigTable objects providing configuration
       information applicable to all linear APS groups."
      ::= { cApsGroups 1 }

  cApsConfigWtr    OBJECT-GROUP
      OBJECTS
      {
          cApsConfigWaitToRestore
      }
      STATUS  current
      DESCRIPTION
      "The cApsConfigTable object that provides information which is
       applicable to groups supporting a configurable WTR period."
      ::= { cApsGroups 2 }

  --  If set operations are not supported neither of the following
  --  two groups are implemented. If sets are supported only one of
  --  these groups is implemented for a linear APS group instance.

  cApsCommandOnePlusOne    OBJECT-GROUP
      OBJECTS
      {
          cApsCommandSwitch
      }
      STATUS  current
      DESCRIPTION
      "The  cApsCommandTable object which is applicable to groups
       implementing the linear APS 1+1 architecture. Also, set
       operations must be supported."
      ::= { cApsGroups 3 }

  cApsCommandOneToN    OBJECT-GROUP
      OBJECTS
      {
          cApsCommandSwitch,
          cApsCommandControl
      }
      STATUS  current
      DESCRIPTION
      "A collection of cApsCommandTable objects which are applicable to
       groups implementing the linear APS 1:n architecture. Also, set
       operations must be supported."
      ::= { cApsGroups 4 }


  cApsStatusGeneral    OBJECT-GROUP
      OBJECTS
      {
          cApsStatusK1K2Rcv,
          cApsStatusK1K2Trans,
          cApsStatusCurrent,
          cApsStatusModeMismatches,
          cApsStatusChannelMismatches,
          cApsStatusPSBFs,
          cApsStatusFEPLFs,
          cApsStatusSwitchedChannel
      }
      STATUS  current
      DESCRIPTION
      "A collection of cApsStatusTable objects providing status
       information applicable to all linear APS groups."
      ::= { cApsGroups 5 }

  cApsChanGeneral    OBJECT-GROUP
      OBJECTS
      {
          cApsChanConfigIfIndex,
          cApsChanConfigRowStatus,
          cApsChanStatusCurrent,
          cApsChanStatusSignalDegrades,
          cApsChanStatusSignalFailures,
          cApsChanStatusSwitchovers,
          cApsChanStatusLastSwitchover
     }
      STATUS  current
      DESCRIPTION
      "A collection of channel objects providing information
       applicable to all linear APS channels."
      ::= { cApsGroups 6 }

  cApsChanOneToN    OBJECT-GROUP
      OBJECTS
      {
          cApsChanConfigPriority
      }
      STATUS  current
      DESCRIPTION
      "The cApsChanConfigTable object that provides information which
       is only applicable to groups implementing the linear APS 1:n
       architecture."
      ::= { cApsGroups 7 }

  cApsTotalsGroup OBJECT-GROUP
      OBJECTS
      {
          cApsConfigGroups,
          cApsChanLTEs
      }
      STATUS  current
      DESCRIPTION
      "A collection of objects providing optional counts of configured
       APS groups and SONET LTE interfaces."
      ::= { cApsGroups 8 }


  cApsMapGroup OBJECT-GROUP
      OBJECTS
      {
          cApsMapGroupName,
          cApsMapChanNumber
      }
      STATUS  current
      DESCRIPTION
      "A collection of cApsMapTable objects providing a mapping
       from sonet(39) InterfaceIndex to group name and channel
       number for assigned APS channels and a list of unassigned
       sonet(39) interfaces."
      ::= { cApsGroups 9 }

  cApsEventOptional NOTIFICATION-GROUP
      NOTIFICATIONS {cApsEventSwitchover, cApsEventModeMismatch,
                     cApsEventChannelMismatch, cApsEventPSBF,
                     cApsEventFEPLF }
      STATUS    current
      DESCRIPTION
      "A collection of SONET linear APS notifications that may
       optionally be implemented."
      ::= { cApsGroups 10 }